Configuration Using the Front Panel (Legal for Trade)
41
3.2.6
Digital Input Menu
Figure 3-14. Digital Input Menu
Parameter
Choices
Description
DIGIN1
DIGIN2
DIGIN3
DIGIN4
Specifies the function activated by digital inputs 1, 2, 3 and 4.
OFF
Sets the Digital Input to perform no function.
ZERO
Same function as the front panel key.
TARE
Same function as the front panel key.
NT-GRS
Net-Gross – same function as the front panel key.
UNITS
Same function as the front panel key.
DSPTAR
Displays the current tare value.
Same function as the front panel key.
CLRCN
Resets the consecutive number to the value specified on the CONSTU parameter (PROGRM
menu).
KBDLOC
Disables the keypad while the digital input is held active.
HOLD
Holds the current display. Releasing this input returns to normal display update mode.
CLRTAR
Clears the tare.
ACCUM
Displays the accumulator.
CLRACC
Clears the accumulator.
BATSTR
Starts a batch process.
BATSTP
Stops a batch; any restart starts the batch at the beginning.
BATRES
Resets the batch process so the pointers are aimed at first batching setpoint.
BATPUS
Pauses a batch, but allows it to restart at the point where it was paused.
BATRUN
A switch that allows a batch to be started. It must be active to allow any batch to run.
If not active, and a BATSTRT input is activated, the batch will abort or reset.
NET
Puts the scale in net mode.
GROSS
Puts the scale in gross mode.
PRI
Puts the scale in primary units.
SEC
Puts the scale in secondary units.
Table 3-15. Digital Input Menu Parameters
DIGIN1-4
OFF
ZERO
TARE
NT-GRS
UNITS
DPSTAR
CLRCN
CONFIG
FORMAT
CALIBR
PROGRM
DIG IN
ALGOUT
PASWRD
USBMEM
MENU
TEST
KBDLOC
BATSTR
BATSTP
BATRES
HOLD
CLRTAR
ACCUM
CLRACC
BATRUN
BATPUS
NET
GROSS
PRI
SEC
Summary of Contents for Legend 480-2A
Page 3: ......
Page 7: ...iv 480 Legend Series...
Page 83: ...76 480 Legend Series...
Page 84: ......