IQ plus 710 Installation Manual
Kind
Description
Batch
Continuous
OFF
Setpoint turned off/ignored.
GROSSSP
Gross setpoint. Trips when the current gross weight matches this value.
√
√
NETSP
Net setpoint. Trips when the current net weight matches this value.
√
√
–RELSP
Negative relative setpoint. Trips at a specific value below the referenced
setpoint.
√
√
PAUSE
Pauses the batch sequence indefinitely. Operator must activate the BATSTRT
digital input to continue processing.
√
DELAY
Delays the batch sequence for a specified time. The length of the delay (in
tenths of a second) is specified on the Value parameter.
√
WAITSS
Wait for standstill. Pauses the batch sequence until the scale is at standstill.
√
TIMER
Tracks the progress of a batch sequence based on a timer.
The timer value, specified in tenths of a second on the VALUE parameter,
determines the length of time allowed between start and end setpoints. The
indicator START and END parameters are used to specify the start and end
setpoints. If the END setpoint is not reached before the timer expires, the digital
output associated with this setpoint is activated.
√
CONCUR
Allows a digital output to remain active over a specified portion of the batch
sequence. Two types of concur setpoints can be configured:
Type 1:
The digital output associated with this setpoint becomes active when
the START setpoint becomes the current batch step and remains active until
the END setpoint becomes the current batch step.
Type 2:
The digital output associated with this setpoint becomes active when
the START setpoint becomes the current batch step and remains active until a
timer expires.
The indicator START and END parameters specify the start and end setpoints.
The timer value is specified in tenths of a second on the VALUE parameter.
√
Table 8-1. Setpoint Kinds