![Rice Lake CLS-920i Installation Manual Download Page 22](http://html1.mh-extra.com/html/rice-lake/cls-920i/cls-920i_installation-manual_1453988022.webp)
CLS-920i Installation Manual
16
3.5
Supplying Power to the Two-Channel iQube Using a Lithium-Ion Battery
If using a wireless version of the CLS-920i, the CLS scale uses a supplied lithium-ion battery to supply power to
the two-channel iQube. The wireless version of the CLS-920i does not come with a coiled cable. The lithium-ion
battery is located on the top of the cover plate in a painted enclosure.
Figure 3-9. Lithium-Ion Battery Location
3.5.1
Lithium-Ion Battery Specifications
Table 3-2. Battery Specifications
Nominal Capacity
6600 mAh
Nominal Voltage
11.1 V
Charging Method
Constant Current
Constant Voltage
Charging Voltage
12.6 V
Charging Current
4.0 A
Charging Time
100% @ 8 hours
Ambient Temperature
Charge
0
°
- +40
°
C
Discharge
-20
°
- +60
°
C
Storage
-20
°
- +50
°
C
Weight (Maximum)
430 g
Dimensions (Maximum)
Depth
22.80 mm
Length
214.0 mm
Volumetric Energy Density
466 Wh/I
Gravimetric Energy Density
167 Wh/kg
Maximum Hours of Charge
24 Hours
Nominal Capacity
6600 mAh
3.5.2
General Precautions
There are some precautions that should be taken when handling lithium-ion batteries.
Handling
• Do not short circuit
• Do not immerse in water
• Do not disassemble or deform battery
• Keep away from excessive heat (+100
°
C) or dispose of battery in fire
• Avoid excessive physical shock or vibration
• Keep out of reach of children
Summary of Contents for CLS-920i
Page 2: ...96312 Rev A CLS 920i 920i Cargo Lift Scale Installation Manual...
Page 3: ......
Page 76: ...CLS 920i Installation Manual 72...
Page 77: ...73 CLS 920i Installation Manual...
Page 96: ......
Page 97: ...PN 96312 11 12...