CLS-920i Installation Manual
5
1.3.3
Operating Modes
The
920i
has two modes of operation:
Normal mode
Normal mode is the weighing mode of the indicator. The indicator displays gross, net, or tare weights as
required, using the secondary display to indicate scale status and the type of weight value displayed. Once
configuration is complete and a legal seal is affixed to the large fillister-head screw on the indicator enclosure,
this is the only mode in which the
920i
can operate.
Setup mode
Most of the procedures described in this manual require the indicator to be in setup mode, including
configuration and calibration.
To enter setup mode, remove the large fillister head screw from the enclosure. Insert a screwdriver or a similar
tool into the access hole and press the setup switch once. The indicator display changes to show scale
configuration menus.
1.3.4
Indicator Operations
Basic
920i
operations are summarized below:
Toggle Gross/Net Mode
Press the
GROSS/NET
key to switch the display mode from gross to net, or from net to gross. If a tare value has been
entered or acquired, the net value is the gross weight minus the tare. If no tare has been entered or acquired, the
display remains in gross mode.
Gross mode is indicated by the word
Gross
(or
Brutto
in OIML mode); net mode is indicated by the word
Net
.
Toggle Units
Press the
UNITS
key to switch between primary, secondary, and tertiary units.
Zero Scale
1. In gross mode, remove all weight from the scale and wait for the standstill annunciator (
).
2. Press the
ZERO
key. The center of zero (
) annunciator lights to indicate the scale is zeroed.
Acquire Tare
1. Place container on scale and wait for the standstill annunciator (
).
2. Press the
TARE
key to acquire the tare weight of the container.
3. Display shifts to net weight and shows the word
Net
on the display.
Remove Stored Tare Value
1. Remove all weight from the scale and wait for the standstill annunciator (
).
2. Press the
TARE
key (or, in OIML mode, the
ZERO
key). Display shifts to gross weight and shows the word
Gross
.
Print Ticket
1. Wait for the standstill annunciator (
).
2. Press the
key to send data to the serial port.
Accumulator Functions
The accumulator must be enabled before use in either normal mode or setpoint operations. Once enabled, weight
(net weight if a tare is in the system) is accumulated whenever a print operation is performed using the
key,
digital input, or serial command. The scale must return to zero (net zero if a tare is in the system) before the next
accumulation.
The
Display Accum
softkey can be configured to display the current accumulator value. Printing while the
accumulator is displayed, or when the setpoint PSHACCUM function is active, uses the ACCFMT print format
Press the
CLEAR
key twice to clear the accumulator.