Configuration
© Rice Lake Weighing Systems
●
All Rights Reserved
25
SCALES Menu, FORMAT Submenu, SPLIT = OFF
Parameter
Choices
Description
Level 4, FORMAT submenu
PRIMAR
DECPNT
DSPDIV
UNITS
Specifies the decimal position, display divisions, and units used for the primary units. See Level 5 submenu
parameter descriptions.
SECNDR
DECPNT
DSPDIV
UNITS
MULT
Specifies the decimal position, display divisions, units, and conversion multiplier used for the secondary units.
See Level 5 submenu parameter descriptions.
TERTIA
DECPNT
DSPDIV
UNITS
MULT
Specifies the decimal position, display divisions, units, and conversion multiplier used for the tertiary units.
See Level 5 submenu parameter descriptions.
ROC
DECPNT
DSPDIV
MULT
TIME
INTERVL
REFRESH
Specifies the decimal position, display divisions, conversion multiplier, time units, update interval, and refresh
interval used for the rate of change units. See Level 5 submenu parameter descriptions.
Level 5 submenus
Primary Units (PRIMAR) Parameters
DECPNT
8888888
8888880
8888800
8.888888
88.88888
888.8888
8888.888
88888.88
888888.8
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the primary unit display.
Value should be consistent with local legal requirements.
DSPDIV
1D
2D
5D
Display divisions. Selects the minimum division size for the primary units displayed weight.
UNITS
lb
kg
g
oz
tn
t
gn
troyoz
troylb
lt
CUSTOM
NONE
OFF
Specifies primary units for displayed and printed weight. Values are: lb=pound; kg=kilogram; g=gram;
oz=ounce; tn=short ton; t=metric ton; gn=grain; troyoz=troy ounce; troylb=troy pound; lt=long ton.
Table 3-3. SCALES Menu, FORMAT Submenu Parameters, SPLIT = OFF
Summary of Contents for 820i
Page 115: ......