3.4 Password Menu
The Password menu is used to set or edit passwords.
Figure 3-6. Password Menu
Enter 999999 to reset either password. This reset can also be used in the event a password is forgotten.
Entering 999999 will reset the configuration of the scale to default values.
3.5 Test Menu
Figure 3-7. Test Menu
Parameter
Settings
Description
CNFG
000000
0
–
999998
The configuration password, if enabled, is used for electronic sealing of the indicator. Once a configuration password has
been set, the existing configuration password is required before the password can be edited. Entering this menu requires
the configuration switch to be pressed.
000000
= no password
USER
000000
0
–
999998
The user password, if enabled, restricts access to the serial and print formatting menus. Once a user password has been
entered, the existing user password is required before the password can be edited.
0000000
= no password
Table 3-8. Password Menu Parameters
Parameter
Choices
Description
ADTEST
—
Displays raw A/D counts
NWGMNT
TOTAL
The number of weighments that exceed value set in WGMNST
OVECAP
The number of weighments that exceed the capacity of the scale as set in the config and format menus, see
WGMNST
0–999999
Weighment Threshold – sets the weight threshold over which WGMNST/Over value will be counted
DEFLT
—
Resets all parameters to factory defaults; at DEFLT, press GROSS/NET, indicator will display
SAVING
and cycle power
Table 3-9. Test Menu Parameters
CNFG
USER
MENU
CONFIG
FORMAT
CALIBR
PROGRM
PASWRD
TEST
IMPORTANT
DEFLT
WGMNST
NWGMNT
ADTEST
TOTAL
OVERCAP
MENU
CONFIG
FORMAT
CALIBR
PROGRM
PASWRD
TEST
Summary of Contents for 482-AG