3.3 Program Menu
Figure 3-5. Program Menu
Parameter
Choices
Description
PWRUPM
GO
DELAY
The power up parameter has two settings. In
GO
mode, the instrument goes into operation immediately after a brief
power up display test; In
DELAY
mode, the instrument performs a power up display test and then enters a 30 second
warm-up period; If no motion is detected during the warm-up period, the instrument becomes operational when the
warm-up period ends; If motion is detected, the delay timer is reset and the warm-up period repeated
REGULA
NTEP
OIML
CANADA
NONE
The regulatory parameter specifies the regulatory agency having jurisdiction over the scale site
CONSNU
000000
0 – 999999
The consecutive number parameter is a read only value; The consecutive number value will increment following each
print operation when the print format used contains the <CN>, or consecutive number formatting token;
NOTE: The initial value of this parameter is set to the start up value specified on the CONSTU parameter.
Changing CONSTU immediately resets the consecutive number used for printing.
CONSTU
000000
0 – 999999
The consecutive number start up parameter specifies the initial consecutive number (
CONSNU
) value used when the
instrument is reset or configured
NOTE: Consecutive numbering starts with number entered
Example: If 100 is entered the first ticketed printed will be 100.
DATE
DATFMT
Specifies the format used to display or print the date
•
MMDDYY
• DDMMYY
• YYMMDD
• YYDDMM
DATSEP
Specifies the date separator character
•
SLASH
• DASH
• SEMI
TIME
TIMFMT
Specifies the format used to display or print the time
•
12HOUR
• 24HOUR
TIMSEP
Specifies the time separator character
•
COLON
• COMMA
SLEEP
NEVER
1MIN
2MIN
5MIN
10MIN
The sleep parameter defines the amount of time to elapse before the instrument will enter the sleep mode when the
following conditions are met: the weight is stable, no keys have been pressed, and the weight is below the sleep weight
threshold
WGTHRH
. A setting of
NEVER
will disable the sleep mode. See
.
NOTE: The sleep mode will activate only if the instrument is operating on the optional internal battery. If the
instrument is connected to an external AC power source, it will not go into sleep mode regardless of the
parameter settings.
Setting the WGTHRH or DDTHRH parameters to 0 also disables the sleep mode
.
Table 3-7. Program Menu Parameters
CONSTU
CONSNU
REGULA
PWRUPM
SLEEP
STDBY
WGTHRH
DDTHRH
DATE
TIME
MENU
CONFIG
FORMAT
CALIBR
PROGRM
PASWRD
TEST