3.2 Calibration Menu
See
Figure 3-4. Calibration Menu
Parameter
Choices
Description
WZERO
CAL
Do not adjust this value after WSPAN has been set;
press
to display
ENTER
then press
to capture the zero value
EDIT
Press to display the current captured zero mV value; the value may be edited as required;
press
to save the edited value
WVAL
—
Press to display the test weight value; The value may be edited as required;
press
to save the edited value
WSPAN
CAL
Press
to display
ENTER
then press
to capture the net span value
EDIT
Press to display the current captured net span mV value; the value may be edited as required;
press
to save the edited value
REZERO
ZERO
(flashing)
Press to remove the weight of the testing apparatus like hooks or chains used during the calibration process;
always use this parameter after WZERO and WSPAN have been set to recapture a new zero value