4.3.4.1 Serial Port Menu
Figure 4-9. Communication – Serial Port Menu
Parameter
Description
trigge
Trigger – Sets the input trigger type;
Settings:
CMD
(default) – Command: allows operation of EDP commands and printing
STRIND – Stream Industrial Scale Data: data is updated up to the configured sample rate; allows operation of
EDP commands and printing
STRLFT
–
Stream Legal for Trade Data: data is updated at the configured display update rate; allows operation of
EDP commands and printing
baud
Baud Rate – Sets the transmission speed for the port (RS-232 only);
Settings: 1200, 2400, 4800,
9600
(default), 19200,
38400, 57600, 115200
bits
Data Bits – Sets number of data bits transmitted or received by the port and specifies the parity bit to odd, even or none
(RS-232 only);
Settings:
8NONE
(default), 7EVEN, 7ODD
STPBIT
Stop Bits – Sets the number of stop bits transmitted or received by the port (RS-232 only);
Settings:
1
(default), 2
termin
Outgoing Line Termination – Sets the termination characters for data sent from the port;
Settings:
CR/LF
(default), CR
eoldly
End of Line Delay – Sets the delay period from when a formatted line is terminated to the beginning of the next
formatted serial output (measured in 0.1 second intervals);
Enter value: 0–255,
0
(default)
echo
Echo – Specifies if characters received by the port are echoed back to the sending unit;
Settings:
ON
(default), OFF
RESPNS
Response – Specifies if the port transmits replies to serial commands;
Settings:
ON
(default), OFF
Table 4-7. Communication – Serial Port Menu Description
Setup
Comm
SERIAL
trigge
BAUD
RS232
BITS
StpBIT
TERMIN
EOLDLY
ECHO
ReSPNS
trigge
TERMIN
EOLDLY
ECHO
ReSPNS
usb