INSTALLATION – SOLAR STORAGE TANK
32
TYPICAL INSTALLATION
– REMOTE GAS BOOSTER 20L, 26L
Solar Premier Loline 160 Water Heater (Outdoor Tank Location) with Remote In-Series 20L, 26L Gas
Booster
Solar Premier Loline 160 Water Heater (Indoor Tank Location) with Remote In-Series 20L, 26L Gas Booster
SOLAR HOT PIPE
Insulated copper pipe. use
a compression nut and olive
SENSOR
CONNECTION
SOLAR PREHEAT
(HOT WATER) OUTLET
Use a union connection &
insulate hot water pipe.
SOLAR CIRCUIT
PRESSURE RELIEF VALVE
AND DRAINLINE
SOLAR COLD PIPE
Insulated copper pipe.
Use a compression
nut and olive.
HOT SENSOR LEAD
OUTDOOR INSTALLATION
INDOOR INSTALLATION
COLD WATER CONNECTION
Cold water connection must
comply with local regulations.
SAFE TRAY WITH DRAIN
As specified in AS/NZS
3500.4
Note: water heater
warranty does not cover
property damage.
TYPICAL INSTALLATION
SOLAR DRAIN BACK 160 WITH REMOTE GAS BOOST
TPR VALVE DRAIN LINE
Drain line must
terminate away from the
base of the water heater.
Discharge point must
comply with
AS/NZS 3500.4
TEMPERATURE
PRESSURE RELIEF
VALVE
GAS BOOSTER
WATER HEATER
HOT WATER OUTLET
Use a union connection
and insulate hot
water pipe
POWER SUPPLY CORD
All electrical work must
be carried out by a
licensed electrical worker.
Power outlet must be
earthed & weatherproof.
GAS SUPPLY PIPE
Isolating valve &
union must be used.
SOLAR PREHEAT INLET
Use a union connection &
insulate pipe.
COLD WATER CONNECTION
Cold water connection must
comply with local regulations
FRONT COVER
SOLAR MONITOR
BASE
Level, stable, impervious
base, designed to avoid
ponding.
FLUE OUTLET
Clearances must comply with
AS 5601 or AS/NZS 5601.1 as
applicable under local regulations.
WALL BRACKET
CABLE TIE
MOUNT
CABLE TIE LEAD
TO PIPE INSULATION
SOLAR HOT PIPE
Insulated copper pipe. use
a compression nut and olive
SENSOR
CONNECTION
SOLAR PREHEAT
(HOT WATER) OUTLET
Use a union connection &
insulate hot water pipe.
SOLAR CIRCUIT
PRESSURE RELIEF VALVE
AND DRAINLINE
SOLAR COLD PIPE
Insulated copper pipe.
Use a compression
nut and olive.
HOT SENSOR LEAD
OUTDOOR INSTALLATION
INDOOR INSTALLATION
COLD WATER CONNECTION
Cold water connection must
comply with local regulations.
SAFE TRAY WITH DRAIN
As specified in AS/NZS
3500.4
Note: water heater
warranty does not cover
property damage.
TYPICAL INSTALLATION
SOLAR DRAIN BACK 160 WITH REMOTE GAS BOOST
TPR VALVE DRAIN LINE
Drain line must
terminate away from the
base of the water heater.
Discharge point must
comply with
AS/NZS 3500.4
TEMPERATURE
PRESSURE RELIEF
VALVE
GAS BOOSTER
WATER HEATER
HOT WATER OUTLET
Use a union connection
and insulate hot
water pipe
POWER SUPPLY CORD
All electrical work must
be carried out by a
licensed electrical worker.
Power outlet must be
earthed & weatherproof.
GAS SUPPLY PIPE
Isolating valve &
union must be used.
SOLAR PREHEAT INLET
Use a union connection &
insulate pipe.
COLD WATER CONNECTION
Cold water connection must
comply with local regulations
FRONT COVER
SOLAR MONITOR
BASE
Level, stable, impervious
base, designed to avoid
ponding.
FLUE OUTLET
Clearances must comply with
AS 5601 or AS/NZS 5601.1 as
applicable under local regulations.
WALL BRACKET
CABLE TIE
MOUNT
CABLE TIE LEAD
TO PIPE INSULATION