Rheem RUUD Commercial Water Heaters Specification Sheet Download Page 1

Medium Duty Gas

Commercial Water Heaters

Available in 60, 75 and 100 Gallon Tank-Type Model

50,000 BTU/Hr. thru 80,000 BTU/Hr.

Rheem-Ruud gas commercial water heaters are specifically designed to
fill the need wherever medium quantities of hot water are required. Typical
applications include small restaurants, apartments and small office buildings.

Construction Features:

• Space saving design

short heights and small jacket
diameters result in greater
installation flexibility.

• Long life tank design

proprietary steel formulation with a
unique coat of high temperature
porcelain enamel to maximize
corrosion resistance resulting in a
superior tank design. Dual
magnesium anode rods are
installed for longer tank life.

• Foam insulation

rigid foam insulation provides
superior insulating qualities,
improves efficiency and reduces
operating costs. Our patented
process of injecting foam into the
insulating cavity adds additional
durability and dent resistance to
the heater jacket.

• Automatic controls

control system is designed to
shut off gas if the pilot flame is
extinguished. Relighting is a safe,
easy procedure. Thermostat
settings to 160°F. A built-in gas
pressure regulator assures even
gas flow.

• Temperature and pressure

relief valve

AGA/ASME rated and factory
installed.

• Full port, full flow brass

drain valve

Certifications and Ratings:

• Efficiency

– these models have been tested according to DOE test

procedures, and meet or exceed the thermal efficiency and standby
loss requirements of current ASHRAE standards (Part of the Federally
mandated Energy Policy Act (EPact)). Also exceeds energy efficiency
codes of all states including California Energy Commission (CEC).

• Safety and construction

– these products are design certified by

CSA Laboratories: a) For operation at 160°F. b) To meet all safety
and construction requirements of ANSI Z21.10.1/ANSI Z21.10.3.
c) As an automatic storage water heater. d) For operation of combustible
floors and alcove installations. e) For combination water heating and space
heating applications. All models are North Carolina and Massachusetts
Code compliant. Certified for a 150 PSI Maximum Working Pressure.

Continued on reverse.

Short

Floor-to-Vent

Heights

Small Jacket

Diameters

Greater

Installation

Flexibility

Reviews: