Address
:
S603-604 Weiye Building Torch Hi-Tech Industrial Development Zone Xiamen, Fujian Province, P.R.C
Tel: 00865925771197 Fax: 00865925771202
Email: [email protected] http://www.rgblink.cn
8
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. System default [STATUS] option, if it is not selected, push the [MENU] up arrow button or
[NEXT] down arrow button, and choose [STATUS].
3. Push the [TAKE] button to confirm, user can view the current device status. The first four
screen show each output to the corresponding input channel. The fifth screen shows the
software version, the sixth screen shows the serial number and the seventh screen shows
the machine address.
How to Set LOGO Display when Power on
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [LOGO].
3. Push the [TAKE] button to confirm, and enter to LOGO setting, push the [NEXT] button
to choose “ON” or “OFF”, then push the [TAKE] button to confirm.
1. Push the [MENU] button on the front panel, and enter to the menu items.
2. Push the [MENU] up arrow button or [NEXT] down arrow button, and choose [EDID].
3. Push the [TAKE] button to confirm.
4. Push any button on output area on the front panel, for example, choose [3] as the output channel.
5. Push any button on input area on the front panel, for example, choose [5] as the input channel.
6. Push the [TAKE] to confirm, and the EDID copy finish.
Note:
When set the EDID, the output interface must be connected to monitors.