Installation of the device  

Proper installation consists in mounting the device on a flat surface with the leads facing down. Only the correct 
installation  of  the  device  ensures  its  proper  operation  and  maintaining  the  device  parameters,  e.g.  casing 
tightness rating to satisfy the IP code.      

NOTICE!  

Before any installation or maintenance operations refer to the manual supplied by the manufacturer. Improper 
connection to the mains power supply, incautious device installation, or improper use may cause the property 
damage,  loss  of  health  or  death  from  electrical  shock!  In  addition,  any  failure  to  follow  the  manufacturer's 
instructions may void your warranty.        

NOTICE! 

Keep in mind that all the components must be mounted with the leads facing down. 

NOTICE! 

It is forbidden to make any additional mounting points or any holes in the device assembly components.     

4.1

 

ZB20 devices 

The ZA20 devices are designed to display time, date, and optionally temperature. For the proper operation of the 
device, it should be correctly configured. As a standard the device is configured using LAN. 

4.2

 

ZB20 configuration 

The configuration process consists in personalising the device through the embedded Web panel. The user, after 
connecting the clock through the LAN inteface, can edit the display parameters of the clock. 

4.2.1

 

Configuration of the device through the embedded website - Web panel  

To connect with the clock, first you should configure the network card of the computer to which it is connected. 
The  proper  configuration  of  the  network  card  can  be  downloaded  from 

http://rgbtechnology.pl/soft/.  Having 

configured  the  network  connection  correctly,  you  can,  through  a  Web  browser,  connect  with  the  embedded 
website (Web panel), where you can personalise the device. On the embedded clock website, you may use the 
following tabs:    

 

TIME 

->  tab allowing you to configure the parameters connected with time; 

DISPLAY 

->  tab allowing you to configure the parameters connected with the device display;   

ALARMS 

->  tab allowing you to configure the parameters connected with alarms (option available in the  

 

 

version with an audible signalling device); 

ADVANCED  ->  tab allowing you to configure the advanced parameters of the device; 
STATUS 

->  tab allowing you to read the device status. 

The detailed description of the tabs is available in the device operation manual instr_hardware_037.  

Summary of Contents for ZB20

Page 1: ...TECHNICAL DOCUMENTATION ZB20 CLOCKS in the Prestige line casing Catalogue index no 301 09 XX Explanatory figure ...

Page 2: ... configuration 5 4 2 1 Configuration of the device through the embedded website Web panel 5 5 Compact clock extender module 6 5 1 Description of the compact clock extender connectors 6 6 Automatic brightness control of the device 6 7 Executive relay module 6 7 1 Executive relay parameters 6 8 Additional options 7 8 1 IR remote control unit 7 8 2 PoE power supply 7 8 3 GPS module 7 8 4 Temperature ...

Page 3: ...ionally available 2 Transport and storage Care should be taken to properly protect the devices so as to eliminate any damage during transport It is forbidden to transport the devices in a collective package without adequate amortisation each device must be packed separately and cannot have freedom of movement during transportation The module should be stored in the temperature not lower than 20 C ...

Page 4: ... power supply unit det F Prestige Line casing det G viewfinder det H M5 cage nuts det I lighting sensor det J IR sensor Fig 1 Explanatory figure 3 1 1 List of display cables 1 Two metre power cord 2 x 0 5mm terminated with power plug 3 2 Dimensions of the ZB20 device All the dimensions shown in the drawings are given in mm Fig 2 3 2 1 Mounting the ZB20 device Fig 3 ...

Page 5: ...gured using LAN 4 2 ZB20 configuration The configuration process consists in personalising the device through the embedded Web panel The user after connecting the clock through the LAN inteface can edit the display parameters of the clock 4 2 1 Configuration of the device through the embedded website Web panel To connect with the clock first you should configure the network card of the computer to...

Page 6: ...pply for GPS and thermometer GND Mass of the system Table 2 6 Automatic brightness control of the device In the standard version a lighting sensor is included The device in response to the intensity of daylight adjusts the brightness of the clock display 7 Executive relay module The device is equipped with an embedded executive relay which enables signalling up to 30 alarms The duration of each al...

Page 7: ...ble in the DTR documentation of the GPS module 8 4 Temperature sensor The temperature sensor Fig 6 is available with two versions of a signal cable length 0 5m and 2m The probe enables measuring and displaying temperature only in C Celsius The detailed description of the temperature probe is available in the DTR documentation according to the catalogue index number Fig 6 8 5 Audible signalling dev...

Reviews: