DTR_102-02-07-001_EN_f
9
5.10
Configuration of the display font
To
change the display font shape,
you should:
1)
Call the configuration menu by pressing the
MENU
key.
2)
Select the
F8
function using the
↑
and
↓
keys and confirm it with the
→
key.
3)
Using the
↑
and
↓
keys, select your preferred font shape and confirm it with the
→
key.
Fnt1
rounded font
Fnt2
seven-segment font
5.11
Restoring the default settings
To
restore the clock default settings by using the remote control,
you should:
1)
Call the configuration menu by pressing the
MENU
key.
2)
Select the
F9
function using the
↑
and
↓
keys and confirm it with the
→
key.
3)
Using the
↑
and
↓
keys, select
res Y
and confirm it with the
→
key.
NOTICE!
The function mentioned above causes the resetting of all the settings of the device, but it doesn't reset the
remote control codes. When the device is equipped with a LAN module, the network settings will be reset as
well.
5.12
Configuration of the temperature offset
To
set the temperature offset
using the remote control, you should:
1)
Call the configuration menu pressing the
MENU
key.
2)
Select the
F10
function using the keys
↑
and
↓
and confirm it with the key
→
.
3)
Using the keys
↑
and
↓
select „
Of Y”
and confirm it with the key
→
.
4)
Using the keys
↑
and
↓
set the appropriate temperature offset value within the range of ±9.9°C and
confirm it with the key
→
.
Of Y
yes
Of N
no
5.13
Configuration of the synchronisation of displaying
To
configure the synchronisation of displaying (content)
using the remote control, you should:
1)
Call the configuration menu pressing the
MENU
key.
2)
Select the
F11
function using the keys
↑
and
↓
and confirm it with the key
→
.
3)
Using the keys
↑
and
↓
select „
SC Y”
and confirm it with the key
→
.
4)
Using the keys
↑
and
↓
set the appropriate synchronisation mode „
SC Cb”
(Slave - Content Basic)
,
„
SC
Cf”
(Slave - Content Full)
,
„
SC Sr”
(Master – Server Content) and confirm it with the key
→
.
NOTICE!
The
only
result of the above configuration is setting / switching over to the selected operational mode. Full
configuration of the synchronisation of displaying requires configuring through the website. For a Slave device
(basic or full), you should configure the IP address of the Master that is the synchronisation source.
5.14
Displaying the information about the signal strength or the disconnection of
the GPS module
To
view the information about the signal strength or the disconnection of the GPS module
using the remote
control, you should:
1)
Call the configuration menu pressing the
MENU
key.
2)
Select the
F12
function using the
↑
and
↓
keys and confirm it with the
→
key.
GP Un (GPS unconnected)
GPS module unconnected
GP NO (GPS no signal)
no signal of the GPS module
GP PS (GPS poor signal)
poor signal of the GPS module
GP GS (GPS good signal)
good signal of the GPD module
Summary of Contents for 102-02-07