Radio Frequency Systems
BD1500W Series Air Dryers User’s Guide
Page 20 of 98
100518834 – Rev. B
6.5.20.3
Push knob in to lock.
6.5.21
Set the Outlet Pressure:
6.5.21.1
Pull the Outlet
Pressure Regulator knob
out (or loosen the
retaining nut – LP
Models).
6.5.21.2
Turn knob until
Outlet Pressure (
OUTP
) reading is at the desired setting.
6.5.21.3
Push knob in to lock (or tighten the retaining nut – LP Models).
6.5.22
Check for air leaks:
NOTE:
This is a general procedure that can be applied to any fitting or hose
that has air pressure in it.
DO NOT SOAP TEST THE HUMIDITY
SENSOR FITTING. DAMAGE TO THE SENSOR MAY OCCUR.
With Compressor NOT running:
6.5.22.1
Listen for any ‘hissing’ sounds which may indicate a fitting or hose
air leak.
With Compressor running:
6.5.22.2
Use a 1-inch paint
brush to dab soapy water
on the air fitting or hose
connection to be tested.
If air bubbles appear at the
connection, this indicates that
air is leaking from the
connection.