Model 8075E Operations Manual v7.21
33
Response “Scanner In”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Data Type Bits
ERROR Bits
1
1
0
Toggle
DATA 0
Not Used, Unmodified
Current Write Mode Value
DATA 1
Not Used, Unmodified
DATA 2
DATA 3
ERROR Bits:
00 = Successful Command, Data Valid
10 = No Response from Read/Write Head
Example Module setups ASCII Mode Serial Readers
Write Tag Command, Serial Reader ASCII Mode “Scanner Out”:
Byte
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
CMD
Not Used, Write With Zeros
0
0
1
Toggle
DATA 00
Data To Write, 16 Bytes in ASCII
DATA 01
DATA 02
DATA 03
DATA 04
DATA 05
DATA 06
DATA 07
DATA 08
DATA 09
DATA 10
DATA 11
DATA 12
DATA 13
DATA 14
DATA 15