Revision 2/2021
14190 E. Jewell Avenue, Suite 4, Aurora CO 80012 - TEL: 303-366-1234 – Proudly Made in the USA
www.rfidinc.com
Model 8075E Operations Manual v7.21
13
Configuring PROFINET - LED Status Lights
There are 4 status LED’s. There are some typos on the silk LED labels on the PCB of versions 0115-01
and 0115-02 Interface PCB’s. LED1 is actually NS, LED2 is actually MS, NS is actually Data Rate,
and MS is actually Link Activity. Below are detailed explanations of each.
LED1
Network Status
•
Off = No power or no IP address
•
Green = Ethernet IP connection established
•
Green Flashing = No Ethernet IP connection established
•
Red = Duplicate IP address detected
•
Red Flashing = Ethernet IP connection timed out
•
Alternating Red/Green = Self-test in progress
LED2
Module Status
•
Off = No power
•
Green = Ethernet IP connection established
•
Green Flashing = No Ethernet IP connection established
•
Red = Mayor Fault (unrecoverable)
•
Red Flashing = Minor Fault (recoverable)
•
Alternating Red/Green = Self-test in progress
NS
= Data Rate
•
Off = 10 Mbps
•
Green = 100 Mbps
•
Alternating Red/Green = Self-test in progress