RF-BM-2652P3
Shenzhen RF-star Technology Co., Ltd.
Page 12 of 20
3 Specifications
3.1 Recommended Operating Conditions
Functional operation does not guarantee performance beyond the limits of the conditional parameter values in the table
below. Long-term work beyond this limit will affect the reliability of the module more or less.
Table 3. Recommended Operating Conditions of RF-BM-2652P3
Items
Condition
Min.
Typ.
Max.
Unit
Operating Supply Voltage
/
1.8
3.3
3.8
V
Operating Temperature
/
-40
+25
+85
℃
Notes: To ensure the RF performance, the ripple wave on the source must be less than ±300 mV.
3.2 Handling Ratings
Table 4. Handling Ratings of RF-BM-2652P3
Items
Condition
Min.
Typ.
Max.
Unit
Storage Temperature
Tstg
-40
+25
+125
℃
Human Body Model
HBM
±2000
V
Moisture Sensitivity Level
2
Charged Device Model
±500
V