7.10.2
Group F1: Quick Start Parameter
Code
Name
Setting range
Default
Min.
Attri.
F1.00
ASF parameter initialization
0: Inactive
1: Restore to FcP default settings
2: Deactivate ASF
0
-
Stop
F1.02
Control mode
0: p/Q control
1: Flow control
2: Pressure control
0
-
Stop
F1.03
Pressure command source
0: Depend on the value of F1.04
1: Select by digital input (F1.04 shows
status)
2: Analog input
3: Communication
0
-
Stop
F1.04
Pressure command selection
0: Pressure command digital setting 0
1: Pressure command digital setting 1
2: Pressure command digital setting 2
3: Pressure command digital setting 3
0
-
Run
F1.05
Pressure command digital setting 0
0.0...1,000.0 bar
10.0
0.1
Run
F1.06
Pressure command digital setting 1
0.0...1,000.0 bar
10.0
0.1
Run
F1.07
Pressure command digital setting 2
0.0...1,000.0 bar
10.0
0.1
Run
F1.08
Pressure command digital setting 3
0.0...1,000.0 bar
10.0
0.1
Run
F1.11
Flow command source
0: Depend on the value of F1.12
1: Analog input (positive / negative)
2: Communication
0
-
Stop
F1.12
Flow command digital setting
0...5,000 rpm
400
1
Run
F1.15
Motor type
0: Others
1: MOT-FC_HOY
1
-
Stop
Bosch Rexroth AG
DOK-SYTROX-FCP5020****-IT01-EN-P
132/201
Frequency-controlled pump drive system Sytronix FcP 5020
Commissioning of Sytronix FcP 5020 System