RD 500 RD51
Parameter Value Assignment
8-3
DOK-RD500*RD51*******-IB04-EN-P
Overview
Guided PARAMETR.
Device control
Term. assignment std
Functions
Device configurat.
Serial communicat.
Diagnosis
Options
DIAGNOSES
P0028 Operating hours
P0029 Operating minutes
P0024 Continuous current
P0025 Peak current long
P0046 Peak current short
P0022 Continuos output
P0023 Peak output long
D0099 Max. Output. frequency
P0027 Max. normaliz.freq.
P0000 Firmware FWC-
P0001 Device ID
P0002 Firmware-version
P0003 Firmware-modul
P0004 Firmware-revision
P0005 Firmware
P0006 Serial number
P0007 Converter number
P0008 EEPROM prog.cykles
P0898 Scratchpad REFU
P0899 Scratchpad customer
SER. COMMUNICATION
P0499 RS232 Baudrate
X11
P0500 SS1 Protocol
X12
P0501 SS1 Baudrate
X12
P0502 SS1 Parity
X12
P0503 SS1 Stop bits
X12
P0504 SS1 Slave Addr.
P0505 SS1 Rx watchdog
P0506 SS1 Rx timeout
P1270 SS6 Baudrate
X13
P1271 SS6 Tx ID No.
X13
P1272 SS6 Rx ID Nor.
X13
P1273 SS6 Tx PZD Clk.
X13
P1274 SS6 Rx watchdog
X13
P1275 SS6 Timeout
X13
START-/STOP-FUNCT.
P0544 Delay after start
P0539 High inertia start
P0043 Inhibit operation
P0044 Inhibit drive OFF1
P0045 timeout for f-null
P0087 Searching mode
P0088 Restart
THERM. MOTOR PROTEC
P0385 Select KTY/PTC X15
P0565 Sel. overload prot.
P0566 Curr. overload prot.
P0532 Fixv. current limit.
U/f-STEUERUNG
P0181 V/f characterist. fa
P0185 V/F charaterist. ua
P0182 V/f characterist. fb
P0186 V/f characterist. ub
P0183 V/f characterist. fc
P0187 V/f characterist. uc
P0184 V/f characterist. fd
P0188 V/f characterist. Ud
P0541 IxR Compensation
P0540 Slip compensation
P0562 Oscillation damping
P0563 Qu. quad. V/f characterist.
CONTROLL SETTING
P0547 Current control Kp
P0548 Current control Tn
P0532 Fixv. current limit
MORE FUNCTIONS
P0282 Rounding ramp up
P0283 Rounding ramp down
P0249 RFG up/down-mode
QUICK-SETUP
P0010 Display language
P0100 Motor type
P0101 Rated speed ASM
P0102 Rated frequency ASM
P0103 Rated current ASM
P0104 Rated voltage ASM
P0106 cos-phi ASM
P0113 Rated speed SM
P0107 Pole number SM
P0112 Rated current SM
P0105 Voltage const. SM
P0178 f-limit motor
P0390 Frequency normalize
P0374 Normalize current
P0026 Pulse frequency
P0072 Source parameter
P0280 Ramp up time
P0281 Ramp down time
P0071 Load factorySetting
DEVICE CONTROL
P0870 ON / OFF in NORMAL
P0871 ON / OFF in TEST
P0872 setpoint in NORMAL
P0873 setpoint in TEST
P0179 V/f character. fmax
P0180 V/F character fmin
P0036 braking resistor
TERM. ASSIGNMENT STD
P0875 Dig. in-, output1
P0876 Dig. in-, output2
P0877 Dig. in-, output3
P0878 Digital input4
P0879 Digital input5
P0880 Digital input8
P0881 Function relay
P0890 Ref.-, analog output
DEVICE CONFIGURAT.
P0071Load factorySetting
P0732 Copy from keypad
P0733 Copy data to keypad
P0064 Parametriz. level
P0037 Display line 1, 2, 3
P0734 Display-contrast
P0768 Illum. display
P0026 Puls frequency
P0072 Source parameter
P0280 Ramp up time
P0281 Ramp down time
NUMERICAL LIST
P0071
Load factorySetting
No action
FUNCTIONS
Control setting
Start-/stop-funct.
Therm. motorprotec
U/f-control
More functions
OPTIONS
Peer-to-Peer
Profibus
Interbus
CAN-Bus
CAN open
Sercos Parameter
Term. strip KL17037
Slot 1 X121
Slot 2 X123
PARAMETRIZATION
quick-Setup
guided parametr.
numerical list
ST510003EN01.FH9
Example of a parameter
in the numerical list
Fig. 8-2: Menu overview
Summary of Contents for RD 500 Series
Page 32: ...2 12 Description of RD51 RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 174: ...5 34 Inverter Technical Data RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 248: ...9 4 Commissioning RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 274: ...14 6 Index RD 500 RD51 DOK RD500 RD51 IB04 EN P...
Page 275: ......