in
chapter 7.4.1 "Category b: Basic Parameters" on page 85
. The fac‐
tory defaults are based on standard applications with standard motors.
3. The frequency command of the converter is set to be 0.00 Hz upon de‐
livery, meaning that the motor will remain static. To start the motor, the
converter settings must be changed with the operating panel.
●
Ensure the plastic enclosure is in place before the device is
powered on. Wait for 30 minutes after powering off, to allow
the DC capacitor being discharged, and do not remove the
upper cover during the period.
6.2.3
Fv Basic Parameter Fast Setting
Use the operating panel to set the necessary parameters based on the appli‐
cation loads and specifications, to allow the converter to start rapidly. A basic
generic parameter fast setting table is given below:
Function code
Name
Setting range
Minimum unit
Factory default
Symbol
b0.04
Converter input supply voltage
380 − 480 V
1
380
◆
b1.09
Acceleration time 1
0.1 − 3600.0s
0.1s
10.0s
◇
b1.10
Deceleration time 1
0.1 − 3600.0s
0.1s
10.0s
◇
S2.00
Rated motor frequency
8.00 − 400.00
Hz
0.01 Hz
50.00 Hz
◆
S2.01
Rated motor rotation speed
1 − 30000 rpm
1 rpm
1440 rpm
◆
S2.02
Rated motor power
0.4 − 1000.0 kW 0.1 kW
Depends on model
◆
S2.03
Rated motor voltage
0 − 480 V
1 V
Depends on model
◆
S2.04
Rated motor current
0.1 − 1000.0 A
0.1 A
Depends on model
◆
Fig.6-5:
Basic parameter fast setting
6.2.4
Example: Commissioning of Converter with Potentiometer
Fv series frequency converter up to 7.5 kW can use the front mounted poten‐
tiometer to set the frequency output by the following procedure.
Sequence Operation
Description
1
Rotate the potentiometer counterclockwise to the
greatest extent.
The initial frequency value is 0.00
2
Press Run key
Enter the command for running, with 0.00 displayed
3
Rotate the potentiometer clockwise (rightwards) slow‐
ly and the displayed value starts to change, until 5.00
is displayed
The motor starts to run
4
Observe:
★ Whether the motor runs in the correct direction
★ Whether the motor runs smoothly
★ Whether there is any abnormal noise or problem
Observe the running: If any abnormality occurs and
stop the motor immediatelyby shutting off the power.
Restart commissioning only after the fault causes
have been removed.
5
Rotate the potentiometer clockwise (rightwards)
The motor accelerates
Bosch Rexroth AG
DOK-RCON02-FV*********IB01-EN-P
Rexroth Frequency Converter Fv
54/219
Commissioning
Summary of Contents for Fv Series
Page 20: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 18 219...
Page 30: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 28 219...
Page 34: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 32 219...
Page 52: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 50 219...
Page 58: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 56 219...
Page 144: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 142 219...
Page 164: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 162 219...
Page 180: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 178 219...
Page 214: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 212 219...
Page 216: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 214 219...
Page 220: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 218 219...
Page 221: ...Notes DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv Bosch Rexroth AG 219 219...