Group E1: Output Terminals
E1.00
Open collector output OUT1
Factory Default 1
Setting range
0 − 11
Minimum unit
1
E1.01
Open collector output OUT2
Factory Default 1
Setting range
0 − 11
Minimum unit
1
E1.02
Relay outputs Pa, Pb and Pc
Factory Default 1
Setting range
0 − 11
Minimum unit
1
Open collector outputs OUT1 and OUT2 and the relay outputs are described
as below:
●
0: Converter is ready to run
–
Terminal output indicating signal when the converter is free of fault
and ready to run after the main circuit and the control circuit power
supplies have been established.
●
1: Converter is running
–
Terminal output indicating signal when the converter is running and
has frequency output.
●
2: DC brake indication
–
Terminal output indicating signal when the converter is in DC brak‐
ing process.
●
3: Converter runs at zero speed
–
Terminal output indicating signal when the converter runs at 0 Hz.
●
4: Frequency/speed arrival signal
–
See related parameter ‘Frequency arrival detection width’ [E1.03].
●
5: Frequency level detection signal (FDT1)
–
See related parameters [E1.04] − [E1.05].
●
6: Frequency level detection signal (FDT2)
–
See related parameters [E1.06] − [E1.07].
●
7: Simple PLC phase completion indication
–
Terminal pulse output indicating signal when each phase is com‐
plete in simple PLC control.
●
8: Under voltage stop
–
Terminal output indicating signal when the converter is at under
voltage.
●
9: Converter over load pre-warning
–
Terminal output indicating signal when the output current exceeds
the set value of parameter ‘Converter over load pre-warning level
setting’ [E1.08].
●
10: Motor over load pre-warning
–
Terminal output indicating signal when the output current exceeds
the set value of parameter ‘Motor over load pre-warning level set‐
ting’ [E1.09].
●
11: Over torque
–
Terminal output indicating signal when the motor torque exceeds
the set value of parameter ‘Torque limit’ [S1.02] in vector control.
Bosch Rexroth AG
DOK-RCON02-FV*********IB01-EN-P
Rexroth Frequency Converter Fv
120/219
Parameter Settings
Summary of Contents for Fv Series
Page 20: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 18 219...
Page 30: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 28 219...
Page 34: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 32 219...
Page 52: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 50 219...
Page 58: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 56 219...
Page 144: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 142 219...
Page 164: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 162 219...
Page 180: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 178 219...
Page 214: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 212 219...
Page 216: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 214 219...
Page 220: ...Bosch Rexroth AG DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv 218 219...
Page 221: ...Notes DOK RCON02 FV IB01 EN P Rexroth Frequency Converter Fv Bosch Rexroth AG 219 219...