Time to movement
(ID=1609)
9.6.7 Time to Stationary (ID=1608)
If ignition is ON and no movement, the event will be generated when TMO
reached. This functionality is 1-enabled, 0-disabled (default).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Scenario Enable
(ID=1607) Time to
movement (ID=1609)
U8
9.6.8 Time to Movement (ID=1609)
If ignition is ON and no movement, the event will be generated when TMO
reached. This functionality is 1 – enabled, 0 – disabled (default).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
255
-
Time to stationary
(ID=1608) Scenario
Enable (ID=1607)
U8
9.6.9 Jamming Detection (ID=1606)
Jamming detection sensitivity can be set to
: 0 – disabled, 1 – low sensitivity, 2
– normal sensitivity (default), 3 – high sensitivity.