Specifications and Installation: rNET-OCC-HV-DT-CM
360° Dual-Technology PIR/Ultrasonic Line Voltage Occupancy Sensor
SPECIFICATIONS
Voltage ................................................................................... 120/277VAC, 50/60Hz
Load Requirements:
Incandescent. .......................................................................... 800W-120VAC, 50/60Hz
Fluorescent ............................................................................. 800VA-120VAC, 1600VA-277VAC, 50/60Hz
Motor .................................................................................... 1/4HP-120VAC, 50/60Hz
Operating Temperature ........................................................... 32°to 131°F (0°to 55°C)
Adjustment Time Delay ............................................................ 5 Sec. to 30 Min.
Test Mode ............................................................................... Delay time is 5 sec., lasts 30 Min. at each time by setting
PIR Adjustment ....................................................................... 50% or 100% (DIP switch 1)
Ultrasonic Adjustment .............................................................. Minimum to Maximum (trimpot 1)
Light Level Adjustment ............................................................. 100 Lux --daylight (trimpot 2)
PIR Coverage .......................................................................... 1600ft
2
Ultrasonic Coverage ................................................................ 1000ft
2
DESCRIPTION
The rNET-OCC-HV-DT-CM 360° Dual-Technology Occupancy Sensor combines advanced passive infrared (PIR) and an
ultrasonic unit. The combined technologies help avoid false triggering. Selectable operating modes allow the sensor to turn a
load on, and hold it on as long as either or both technologies detect occupancy. After no movement is detected for the selected
time delay, the lights will switch off.
COVERAGE PATTERN
The rNET-OCC-HV-DT-CM provides a 360° coverage pattern. The coverage shown represents walking motion at a mounting
height of 9 feet. For building spaces with lower levels of activity or with obstacles and barriers, coverage size may decrease.
(13.4m)
44
ft
30
ft x 30 ft
(9.14
m x 9.14m
)
PIR
Coverage
Ultrasonic
Coverage
Figure 1