Specifications and Installation: rNET-OCC-HV-DT-CM 
360° Dual-Technology PIR/Ultrasonic Line Voltage Occupancy Sensor 

 

 

 

SPECIFICATIONS

 

Voltage ...................................................................................  120/277VAC, 50/60Hz 

Load Requirements: 
Incandescent. .......................................................................... 800W-120VAC, 50/60Hz 
Fluorescent ............................................................................. 800VA-120VAC, 1600VA-277VAC, 50/60Hz 
Motor   ....................................................................................  1/4HP-120VAC, 50/60Hz     
Operating Temperature  ........................................................... 32°to 131°F (0°to 55°C)  
Adjustment Time Delay ............................................................ 5 Sec. to 30 Min. 
Test Mode ............................................................................... Delay time is 5 sec., lasts 30 Min. at each time by setting 
PIR Adjustment ....................................................................... 50% or 100% (DIP switch 1) 
Ultrasonic Adjustment ..............................................................  Minimum to Maximum (trimpot 1) 
Light Level Adjustment ............................................................. 100 Lux --daylight (trimpot 2) 
PIR Coverage .......................................................................... 1600ft

2

 

Ultrasonic Coverage ................................................................ 1000ft

 

DESCRIPTION 

The rNET-OCC-HV-DT-CM 360° Dual-Technology Occupancy Sensor combines advanced passive infrared (PIR) and an 
ultrasonic unit. The combined technologies help avoid false triggering. Selectable operating modes allow the sensor to turn a 
load on, and hold it on as long as either or both technologies detect occupancy. After no movement is detected for the selected 
time delay, the lights will switch off.  

 
 

COVERAGE PATTERN

 

The rNET-OCC-HV-DT-CM provides a 360° coverage pattern. The coverage shown represents walking motion at  a mounting 
height of 9 feet. For building spaces with lower levels of activity or with obstacles and barriers, coverage size may decrease. 

 

(13.4m)

 

44

 

 ft

 

30

 

 ft x 30 ft

 

(9.14

 

m x 9.14m

 

)

 

PIR

 

Coverage

 

Ultrasonic

 

Coverage

 

Figure 1

 

Summary of Contents for rNET-OCC-HV-DT-CM

Page 1: ...inimum to Maximum trimpot 1 Light Level Adjustment 100 Lux daylight trimpot 2 PIR Coverage 1600ft2 Ultrasonic Coverage 1000ft2 DESCRIPTION The rNET OCC HV DT CM 360 Dual Technology Occupancy Sensor co...

Page 2: ...rease the mounting height you decrease the range and increase the sensitivity to smaller motions Conversely when you increase the height you increase the range and decrease the sensitivity to smaller...

Page 3: ...n off the power at the circuit breaker before installing Refer to the wire diagram of the sensor see Figure 4 and connect the wires of ceiling sensors as followed by using the wire nuts provided 1 Con...

Page 4: ...ensor in the J Box so that the mounting screws on the box match the key holes on the sensor s rear housing 5 Push the sensor up into the J Box and twist it so that the mounting screws are seated in th...

Page 5: ...e 5 of 7 Ambient Light Level Adjustment Trimpot 2 Adjustable 100Lux to daylight clockwise SENSOR ADJUSTMENT There is a 40 second warm up period when power is first applied The sensors are factory pres...

Page 6: ...0 square feet Trigger Mode Switches 2 3 4 The sensor has 6 trigger options set with DIP switches 2 3 and 4 In the trigger mode DIP switch setting table Both requires motion detection by the PIR and th...

Page 7: ...ashes when movement occurs Red LED flashes 1 Reduce PIR sensitivity by setting to 50 DIP Switch 1 Unwanted Sensor Activations LED flashes Possible causes 1 Sensor located too close to HVAC or VAV vent...

Reviews: