45
2.
The Microphone or Speaker lost connection with the Base Station for more than
5 minutes and therefore shut down. It should be returned into reach of the Base
Station and switched on again to be reactivated.
Dialer Low Battery
When the Dialer
experiences a low battery it will display a ‘low battery’ notification on
the screen. The Dialer should be returned to the charger until the battery status on the
home screen shows a full charge.
Dialer Link Lost
If the FLX Dialer loses connection to the FLX2
Base Station it will display a ‘connection
lost
’ notification on the screen and starts emitting a warning sound. The Dialer should
be moved back into range of the Base Station at which point it will reconnect
automatically.
Base Power Lost
If the FLX2 Base Station loses power, it will disconnect all telephone calls, analog audio
inputs/outputs and will disconnect from the FLX Dialer, Speaker, and Microphones.
Check to make sure that the power adapter is still connected to the FLX2 Base Station.
Once the FLX2 Base Station is powered back on, the Dialer, Speaker and Microphones
will reconnect automatically.
Microphone, Speaker, or Dialer not connecting to Base Station
If any of the components of the FLX2 Conference Phone indicate that they are
searching for the Base Station, or lost the connection to the Base Station, please follow
these steps:
1.
Is the Base Station powered up
– the Status LED on the back of the Base Station
should have green double flashes about every second. If not, please power up
the Base Station. All components should automatically connect to the Base
Station after a few seconds.
2.
The Base Station is powered up, but the Status LED indicates a fault by missing
every fifth green double flash. Power down and power up the Base Station. All
components should reconnect to the Base Station after a few seconds. If the
fault in the Base Station continues (every fifth double flash is skipped) please
contact Revolabs support.
3.
Are the Dialer, Microphone, and Speaker out of reach of the Base Station?
Please bring the components closer to the Base Station to see whether this
resolves the issue.
4.
Power down the Base Station, the Microphones, the Dialer, and the Speaker.
Now power up the Base Station. Once the Base Station is powered up (double
green flashes of the Status LED), power up the Dialer, and then the Microphones
and the Speaker. The components should now connect to the Base Station.
5.
If the components still do not connect to the Base Station, please re-pair the
components that have not connected to the Base Station, beginning with the
Dialer. How to pair the components is explained on page 41.
6.
If the components still do not connect to the Base Station, please contact
Revolabs support.