These appliances have been tested and found to comply with the 
established standards for GAS-FIRED ROOM HEATERS and 
DIRECT VENT WALL FURNACES in CANADA and the      
U. S. A. as follows: CANI-2.17-M91 (R1999)  ANSI-Z21.86-
2004  CSA 2.32-2004 

INSTALLATION AND OPERATING 

INSTRUCTIONS

 

DIRECT VENT SPACE HEATER MODELS    

 

 

 

 
 
 
 
 
 
 
 
WARNING: 

Improper installation, adjustment, alteration, service or maintenance can cause 

injury or property damage. Refer to this manual. For assistance or for additional information, 
consult a qualified installer, service agency or gas utility. 

 

PLEASE KEEP THESE OPERATING INSTRUCTIONS FOR FUTURE REFERENCE 

Rev. September 2005 

 

Model No.'s:  

 

DVH150 N 

DVH150 P

 

(Natural  Gas)      
(Propane Gas) 

 

For Your 

Safety 

If you smell gas: 
1. Open windows. 
2. Don't touch electrical switches. 
3. Extinguish any open flame. 
4. Immediately call your gas supplier. 

For Your 

Safety 

Do not store or use gasoline or other 
flammable vapors and liquids in the 
vicinity of this or any other appliance. 

f i r e - p a r t s . c o m

Summary of Contents for DVH150 N

Page 1: ...IRECT VENT SPACE HEATER MODELS WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual For assistance or for additional information consult a qualified installer service agency or gas utility PLEASE KEEP THESE OPERATING INSTRUCTIONS FOR FUTURE REFERENCE Rev September 2005 Model No s DVH150 N DVH150 P Natural Gas Propane Ga...

Page 2: ...ciations for both safety and efficiency Please take a moment now to acquaint yourself with these instructions and the many features of your new REVERSO SUPREME space heater GENERAL INFORMATION All REVERSO gas fired appliances must be installed in accordance with these instructions Carefully read all of the instructions in this manual first Consult the building authority having jurisdiction to dete...

Page 3: ...he appliance Always connect this gas appliance to specified vent materials and vent flue gases to the outside of the building envelope Never vent to another room or inside a building Make sure that the vent is properly sized and follows the instructions for minimum maximum vent provide the proper draft Inspect the venting system annually for blockage and any signs of deterioration To prevent injur...

Page 4: ... Propane gases designated in the model number by the suffix N Natural gas or P Propane FOR INSTALLATIONS ABOVE SEA LEVEL NATURAL GAS MODELS In Canada and the U S A these appliances are certified for installation at altitudes of 0 4 500 In the U S A the appliance must be derated 4 for every 1 000 above 4 500 elevations PROPANE MODELS In Canada these appliances are certified for altitudes of 0 2 000...

Page 5: ...to operate the REVERSO SUPREME DVH 150 series if these models have a Millivolt gas control which uses the pilot flame to generate sufficient power to operate the main burner whenever the manual switch provided is turned on See Wiring Diagram Below The appliance does come fully equipped with a 120 volt household plug which when connected supplies electrical power for the air circulation fan When co...

Page 6: ...he building they are approved for bedroom installations They may be installed on any flat hard surface combustible or otherwise They can be located within the allowable clearances to combustibles against the wall in a corner or out in the center of the room if desired See diagram 1 fire parts com ...

Page 7: ...the CAN CGA B149 1 or 2 Installation Code For U S A gas installations follow either local codes or the current edition of the National Fuel Gas Code ANZI Z223 1 GAS PIPE TESTING The appliance and its shut off valves must be disconnected from the gas supply piping system during any pressure testing where the pressure exceeds 1 2 PSIG 3 45 kpa Always check for gas leaks with a soap and water solutio...

Page 8: ...OF 8 AND A MAXIMUM LENGTH OF 18 TO THE OUTSIDE WALL TERMINAL PLEASE SEE DIAGRAM ON PAGE 8 WITH A MINIMUM VERTICAL RISE OF 1 HORIZONTAL RUNS OF FROM ONE TO THREE FEET ARE PERMITTED TO REACH THE OUTSIDE VENT TERMINATION FOLLOW THE VENTING TABLE FOR OTHER CONFIGURATION BY FOLLOWING THIS TABLE PRECISELY BEFORE BEGINNING THE INSTALLATION YOU CAN ENSURE AN APPROPRIATE OUTSIDE LOCATION FOR THE VENT TERMI...

Page 9: ...EVERSO SUPREME gas dealer or your local gas supplier This appliance must not be operated if it or the gas controls have been under water Contact a qualified gas technician for service before attempting to operate This appliance should be serviced regularly to ensure continuing safety and efficiency contact a qualified technician at least annually For cleaning turn the gas control knob to the OFF p...

Page 10: ...10 fire parts com ...

Page 11: ...J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 Inches 30 cm minimum K Clearance to a mechanical air supply Inlet 6 feet 1 8 m minimum L Clearance above paved side walk or paved driveway located on public property 7 feet 2 1 m minimum M Clearance under veranda porch deck or balcony 18 Inches 45cm minimum A vent shall not terminate di...

Page 12: ...rner assembly 5 Ensure the door is properly fastened and all of the door retaining screws are back in place after cleaning before attempting to relight the appliance NOTE This appliance is equipped with Neo Ceram Glass pilot viewing port which can only be broken by a significant impact or misuse REVERSO SUPREME OPTIONS 1 Fireflick remote control kit 2 Wall thermostat 3 Sidewall vent kit 4 Roof ven...

Page 13: ... 4 Back Cabinet Frame 14 Top Baffle 24 Screen 5 Support Leg Cabinet Frame 15 Center Baffle 25 Door 6 Baffle Cabinet Frame 16 Bottom Baffle 26 Hinge Door 7 Combustion Chamber Frame 17 Bracket Center Baffle 27 Spring Door 8 Top Combustion Chamber 18 Heat Shield 20 Knob Door 9 Bottom Combustion Chamber 19 Fan MTG Bracket 10 Transition 20 Control MTG Bracket fire parts com ...

Page 14: ...14 fire parts com ...

Page 15: ...15 fire parts com ...

Page 16: ...16 fire parts com ...

Page 17: ... PART HAS BEEN UNDER WATER IMMEDIATELY CALL A SERVICE TECHNICIAN TO INSPECT THE FIREPLACE AND REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN UNDER WATER LIGHTING INSTRUCTIONS WARNING THE GAS VALVE HAS AN INTERLOCK DEVICE WHICH WILL NOT ALLOW THE PILOT BURNER TO BE LIT UNTIL THE THERMOCOUPLE HAS COOLED ALLOW APPROXIMATELY 60 SECONDS FOR THERMOCOUPLE TO COOL 1 STOP READ TH...

Page 18: ...ll provide replacement parts at no charge except for those parts listed below Reverso shall not be responsible for any labour installation construction transportation or other related costs The following parts are only guaranteed for the first year of the warranty Burner Assembly Valve Controls and Blower Assembly This warranty may not be extended by our representatives in any manner whatsoever Th...

Reviews: