A M E R I C A N C O A C H P A T R I O T O W N E R ’ S M A N U A L
A M E R I C A N C O A C H // P A T R I O T
S E C T I O N 9 //
1 0 1
■
STARTING THE LP GENERATOR
After performing the safety checks above, you can proceed to
start the generator as follows:
STEP 1
Press and hold the “Start” icon button at the Firefly
display� This will engage the electric starter to turn over
the generator�
STEP 2
Once the generator starts, allow it to warm up to operating
temperature� This will take a few short minutes depending
on the outside ambient temperature�
STEP 3
Check again for any fuel or exhaust leaks and to ensure
there are no obstructions that could cause exhaust
gasses to enter the coach�
STEP 4
If you started the generator using the rocker switch at
the generator itself, replace the and lock the service
access hatch�
With the generator running normally and warmed up, you may begin
to apply electrical loads� Start appliances that consume the highest
starting amperage first, such as the roof air conditioner. Do not exceed
the total maximum amperage load (20.8 amps) or the circuit breaker
on the generator will trip� As electrical loads are applied, the tone of
the generator exhaust sound will deepen, indicating it is now operating
under load�
WARNING
Do not engage the start button for more than 10 seconds.
Allow 30 seconds between starting attempts. Refer to the
“Troubleshooting” section of the Onan RV Genset Operator’s
Manual if it fails to start. Excessive cranking will damage the
generator’s starter motor.
Before shutting down the generator, remove the heavy loads so that
it has an opportunity to cool down� This will reduce premature wear
on the internal components and seals on the generator� Run the
generator for at least two minutes without a load (up to 5 minutes
under high ambient temperature and humidity conditions).
warning
To manually stop the generator, touch the “Stop” icon button on the
Firefly network display, or press the rocker switch on the generator down
to stop it� If the AGS is active, it may attempt to immediately restart the
generator if the battery bank is at or below the “Start At” voltage�
Excessive loads will cause the circuit breaker on the generator to trip�
This is designed to protect the generator from damage�
Should you
need to reset the breaker, follow these procedures:
STEP 1
Remove the service access hatch from the generator,
using a flat-blade screwdriver or a coin. Twist the lock ¼
turn counterclockwise to open and remove the cover� For
coaches equipped with the Onan QG 2500i LP Generator
simply turn the thumb latch� Gently set it aside�
Summary of Contents for Midwest Automotive Design American Coach Patriot 2022
Page 1: ...PATRIOT O W N E R S M A N U A L...
Page 2: ...574 522 4878 midwestautomotivedesigns com 1826 Leer Drive Elkhart Indiana 46514...
Page 3: ...Table of Contents...
Page 7: ...SECTION 1 Introduction...
Page 10: ......
Page 11: ...SECTION 2 Limited Warranty...
Page 15: ...SECTION 3 General Information...
Page 18: ......
Page 19: ...SECTION 4 Safety...
Page 36: ......
Page 37: ...SECTION 5 Before You Go...
Page 50: ......
Page 51: ...SECTION 6 Exterior Features and Care...
Page 65: ...SECTION 7 Interior Features Functions and Care...
Page 77: ...SECTION 8 Plumbing and Sanitation Systems...
Page 90: ......
Page 91: ...SECTION 9 Electrical Systems...
Page 108: ......
Page 109: ...SECTION 10 Appliances...
Page 119: ...SECTION 11 Infotainment System...
Page 127: ...SECTION 12 Winterization and Storage...
Page 135: ...SECTION 13 Maintenance...
Page 156: ......
Page 157: ...SECTION 14 Schematics and Illustrations...
Page 172: ......
Page 173: ...SECTION 15 Index...
Page 176: ......
Page 177: ...574 522 4878 midwestautomotivedesigns com 1826 Leer Drive Elkhart Indiana 46514...