1. Unscrew the cover with the supply hose from the empty canister.
2. Remove the supply tube from the empty canister.
3. Remove the empty canister from the MagicBox.
4. Place the full electrolyte canister in the MagicBox.
5. Insert the supply hose into the full electrolyte canister and screw on the lid.
6. Remove the lid (without a hole) from the full canister and screw it onto the empty electrolyte
canister.
If you want to work immediately, leave the lid open with one turn.
7.2 Fill the electrolyte canistern
If you order the "MagicBox" with an empty electrolyte canister, the canister needs to be filled on
your own.
Security notice
Be aware of all safety regulations when handling chemicals.
Use your personal protective equipment
➢
Safety glasses
➢
Protective gloves
➢
Protective clothing
1. Take the electrolyte canister out of the MagicBox.
2. Unscrew the cover with the supply hose.
3. Fill the canister with the appropriate electrolyte.
4. Screw the lid and the hose back onto the canister.
If you want to work immediately, leave the lid open with one turn.
1, 2, 3. 4, 5 6
full
empty
empty
lid
1 2 3 4