Summary of Contents for vision

Page 1: ...Vision VENT Technical documentation RETIGO 2011 ...

Page 2: ......

Page 3: ...mited 3 SAFETY INSTRUCTION 5 1 General safety data 5 2 Operating personnel designation 5 3 Perfect condition 5 4 Safety rules for work with the RETIGO Company products 5 TECHNICAL DATA 6 TRANSPORT AND INSTALLATION 7 1 Appliance transportation 7 2 Waste disposal 7 3 The Appliance installation 7 4 Eletrical connections of the air condensation hood 8 5 The hood set up and control 10 MAINTANCE AND CLE...

Page 4: ...ETIGO hoods are designed for extraction and condensation of vapors emanating from the Vision mo dels of the RETIGO combi steamers They are control led by the combi steamer s electronics After the combi steamer door is shut and prepa ration of food is triggered the temperature inside the cooking chamber is carefully monitored If this tempe rature exceeds the temperature necessary for the hood activ...

Page 5: ...leaning and maintenance If any steps of the process are unclear to you seek additional infor mation from your deal er or the manufacturer 5 1 Used symbols The symbols we use are designed to signal activi ties which may affect your safety or health They also attempt to help you with preventive checks The good advice symbol s role is to make your work easier Damage Prevention This symbol informs you...

Page 6: ... and will remove all responsibility for consequent damages from the RETIGO Company Accidental mistakes or omissions are covered within the contractual warranty obligations negotiated in the contract when elimina ting all further claims Any claims for damages no matter the legal rea son applied are not possible ...

Page 7: ...ation from your dealer or manufacturer by mail or by phone 2 Operating personnel designation Designate a specific person who will operate the appliance and train him or her This device is designed for professional use only and must be operated solely by qualified and properly trained personnel 3 Perfect Condition Operate this appliance only while it is in a perfect condition Do not remove any safe...

Page 8: ...CHNICAL DATA Bas i c technical parameters Weight 60 kg Dimensions d x w x h 1130 x 930 x 412 mm Noise min max 63 dB 68 dB Airflow max 1000 m3 h Input max 400 W Required voltage 1NN 200V 230V 50 60 Hz 2N 200V 230V 50 60 Hz ...

Page 9: ...stics 2 2 Liquidation after useful life expiration Please deposit the sheet metal parts to a waste disposal centre for proper liquidation 3 The Appliance Installation 3 1 Preparation for the Appliance Installation Before you start the hood installation please discon nect the combi steamer from the electric sup ply Installation of the hood must be performed in accor dance with all relevant rules an...

Page 10: ...ackage Start with the two side filters as shown in picture III they are marked with edging and then place the middle filter between them Picture III Grease filters installation 3 3 Check the installation location Make sure that the electrical power supply meets the parameters listed on the manufacturer s label This will prevent possible installation complicati ons 4 Electrical connections of the h...

Page 11: ...ency converter as seen in picture Nr 3 Pict 3 The bushing in the power panel Connecting the UTP cable Run the control UTP cable from the hood towards the combi steamer s base In the base near the supply cable opening you will find capped holes Break one of them and to this space insert the cable grommet attached to the UTP cable See picture Nr 4 In the combi steamer power panel there is a rubber o...

Page 12: ... and perform protec ted coupling 5 The hood set up and control In order for the hood to work properly it is necessa ry to allow communication between the hood and the combi steamer in the combi steamer s service menu Setting the hood on the combi steamer s con trol panel Blue Select Service at the combi steamer display then choose PIN click OK in the service menu select the item Configuration then...

Page 13: ... Solution of the problem Err 62 5 Error or interruption in the data communication between the hood and the combi steamer Power sup ply interruption Check the data hood communication cable and its correct connection Make sure the air condensati on hood is plugged into the power supply Err 63 5 64 5 65 5 66 5 70 5 71 5 72 5 73 5 Data communications error Error or interference of data com munication ...

Page 14: ...gether with the motor pos 5 Remove the metal sheet plate with the motor from the exchanger The hood description Picture V 1 Vapor drap 2 Division partition 3 Connector 4 Heat exchanger 5 Motor The RETIGO Company recommends regular clea ning and maintenance of the appliance by a authorized service company Excessive wear and tear and possible damage to the appliance can be prevented only by re gular...