background image

user guide

ReSound Essence ITE, ITC & CIC

ES50, ES50-D, ES50-P, ES50-DP, 

ES30, ES30-D, ES30-P, ES30-DP

ES10, ES10-P

Summary of Contents for Essence ES10

Page 1: ...user guide ReSound Essence ITE ITC CIC ES50 ES50 D ES50 P ES50 DP ES30 ES30 D ES30 P ES30 DP ES10 ES10 P...

Page 2: ...nformation in this booklet Proper understanding and use of your new GN ReSound hearing instrument will allow you to derive maxi mum hearing benefit This instruction manual covers the following ReSound...

Page 3: ...earing instru ment will always start in program 1 To read more on this sub ject turn to page 12 Turning your instrument off when you are not using it will in crease the battery life At night turn off...

Page 4: ...or rectly into the slot Instrument type Battery type ES10 ES10 P CIC CIC P 10A zinc air ES30 ES30 D ES30 P ES30 DP ITC ITC D ITC P ITC DP 312 zinc air ES50 ES50 D ES50 P ES50 DP ITE ITE D ITE P ITE DP...

Page 5: ...custom shell fits correctly into your ear If your hearing instrument irritates your ear in any way and prevents you from wearing your hearing in strument please contact your hearing care professional...

Page 6: ...volume control that al lows you to set and control the volume manually This option is not available for CIC instruments Duringthefittingoftheinstrument your hearing care practitioner will select an op...

Page 7: ...just 1 beep You can also get back to programme 1 by turning your instru ment off and then on again Your Programme Environments Let your Hearing Care Professional fill out the following table No Progr...

Page 8: ...es theatres and cinemas have in duction loop systems In these particular rooms the induction loops transmit wirelessly the sound of the presenter or show At home radio or television can be connected t...

Page 9: ...Outlet Filter Cleaning the Sound Outlet Your ReSound Essence hearing instrument may be equipped with a sound outlet filter consult your hearing care profes sional This filter is located at the end of...

Page 10: ...not optimal If you experience additional problems not addressed in this guide please contact your hearing care professional POSSIBLE REMEDY Turn on Replace battery Insert battery properly Change filte...

Page 11: ...ring instrument Different types of radiation e g from NMR MRI or CT scan ners may damage the hearing instrument Therefore do not wearthehearinginstrumentduringtheseorothercorrespon ding scanning proce...

Page 12: ...ery warning 5 7 Maintenance 15 On off switch 5 Precautions 20 Programme Selector 8 12 Technical data 20 Telecoil use 13 14 Telephone use 13 17 Troubleshooting guide 18 19 Volume control 11 14 18 Any i...

Page 13: ...Weston on the Green Oxon OX25 3SX Tel 0 1869 343 500 Fax 0 1869 343 466 www gnresound co uk Australia GN ReSound Pty Ltd Unit R1 Regent Park Estate 391 Park Road Regent Park NSW 2143 Tel free 1800 65...