INTERFACE SPECIFICATIONS
SeaBat 8160
Operator‟s Manual
Page 76
October 6, 2011
Version 5
C.3.3 CTD Data
The processor currently accepts data in the following formats.
C.3.3.1
SeaBird CT
Message - TTT.TTTT,CC.CCCCC,SSSS.SSSS,VVVVV.VVV<CR><LF>
Table 17: SeaBird CT Message Format
Field
Description
Unit
TTT.TTTT
Temperature
Celsius
CC.CCCCC
Conductivity
Siemens Per meter
SSSS.SSS
Salinity
Parts per Thousand
VVVVV.VVV
Sound Velocity
Meter per Second
C.3.3.2
SeaBird CTD
Message:
TTT.TTTT,CC.CCCCC,PPPPP.PPP,SSSS.SSSS,VVVVV.VVV<CR><LF>
Table 18: SeaBird CTD Message Format
Field
Description
Unit
TTT.TTTT
Temperature
Celsius
CC.CCCCC
Conductivity
Siemens Per meter
PPPP.PPP
Pressure
Decibars
SSSS.SSS
Salinity
Parts per Thousand
VVVVV.VVV
Sound Velocity
Meter per Second
C.3.3.3
AML Smart Sensor
Message:
SVVVV.VVS<CR><LF>
Table 19: AML Smart Sensor Message Format
Field
Description
Unit
VVVV.VV
Sound Velocity
Meter per Second
S
Space Character