SYSTEM OPERATION
SeaBat 7125 SV2 Operator‟s Manual
Page 78
July 25, 2011
Version 3
When switching, the new active Primary Display will briefly show this message:
All sonar control tabs will now be dedicated the active frequency. For synchronization of
the Primary Display Settings for both frequencies, see
section 5.7.4 below
5.7.2 Detection Settings
The Detection Settings tab allows the operator to apply range and/or depth filters (depth
gates) to the bottom detection process to aid in noise reduction and to correct for a tilted
sonar head. Gate lines (filter lines) can be optionally displayed on the sonar image. For
details, see
section 5.7.4 below
A yellow highlight of text fields and check boxes indicates that the data was changed
since last update and has not yet been applied.
The color of the Apply button indicates if data is stored locally by the UI or sent directly
to the center:
Red:
Data is stored locally and gates are inactive
Green:
Data is sent to center and gates are active
Figure 21: Sample of Detection Settings Tab
The last user settings are stored and will be recalled upon system startup.
For examples on how to use this setting, see
section 6.2.8 Use of Gates
Summary of Contents for SeaBat 7125 SV2
Page 2: ...This page intentionally left blank...
Page 211: ......