SYSTEM CONFIGURATION
SeaBat 7125 SV2 Operator‟s Manual
Page 19
July 25, 2011
Version 3
Water Column Data:
Use the radio buttons to select either amplitude only or
full beam data for display in the A-scan window to the left of the sonar wedge
and for output over the Ethernet broadcast or storage to a Windows file.
o
Signal Analysis Mode: Magnitude and phase data are both transmitted
to the user interface. This allows for phase data to be analyzed in the
A-scan displays. As this option increases the CPU usage for the
SeaBat, RESON recommends that this option only be used when
inspecting phase data.
o
Operator Mode: The SeaBat extracts only the magnitude from the ping
data. This data is then compressed to a maximum of 1024 samples. If
less than 1024 samples are received in the ping, no compression
occurs. This feature improves the performance of the system, but
eliminates the ability to inspect the phase data.
General QC Displays:
Select additional displays:
o
Sidescan: Select the check box to display the Side Scan tab.
Snippets Control:
Select the check box to display the Snippets tab.
o
Sample Window Maximum: Not available.
o
Maximum Sample Window (based on range): Not configurable.
4.2.2 UDP Broadcasting
The UDP Broadcasting dialog allows the operator to broadcast selected records to a
remote IP address and UDP port.
From this dialog, you can:
Add, edit, or delete
broadcast addresses.
Start or stop the
broadcast process.
Save or load an existing
broadcast configuration.