background image

RE319_DSC_Flood_Temp_Instructions 

Page 1 of 4 

27-Jan-15 

24-Hour Tech Support Line: (715)808-0164

 

www.ResolutionProducts.com

 

 

 

 

 

RE319 

Flood/Temp Range, DSC

®

-Compatible 

Home Disaster™ Sensor

 

 

Features

 

 

Tri-Mode Environmental Sensing: 

o

 

Flood/Moisture Sensor 

o

 

Freeze – for Furnace Failure 

o

 

Overheat – for Furnace runaway or Air Conditioning failure. 

 

3 unique wireless IDs or Loops: one for each function 

 

Cover tamper. 

 

Strong, reliable RF signal. 

 

8-10 year battery life on CR123A battery. 

 

Low Battery indication. 

 

3.3x1.4x1.1 inches. 

 

Key Instructions

 

 

Battery “+” faces towards spring. 

 

Activating Zones 

 

Flood Zone operates on unit when it comes from the factory.  The 
enrolling actions (listed next) activate the Freeze and Overheat Zones. 

 

ACTIVATE ONLY THE ZONES YOU NEED  
(In order to extend battery life and prevent RF pollution): 

 

Enrolling: Place control panel in enroll mode… then for… 

 

Flood - Zone 0:  ESN ends in “0” (this ESN is printed on sensor): 

 

Enroll by: 

 

…Shorting and opening Flood Sensor 

 Sensor sends Flood Alarm & enrolls. 

 

Freeze - Zone 1:  ESN ends in “1”: 

 

Enroll by: 

 

Holding Tamper down, 

 

Leaving magnet away from Reed Switch,  

 

…while installing battery. 

 Sensor sends Freeze-Alarm & enrolls. 

 

Overheat – Zone 2:   ESN ends in “2”: 

 

Enroll by: 

 

Holding Tamper down, 

 

Having magnet next to Reed Switch, 

 

…while installing battery. 

 Sensor sends Overheat Alarm & enrolls. 

 
 

RE319_DSC_Flood_Temp_Instructions 

Page 2 of 4 

27-Jan-15 

24-Hour Tech Support Line: (715)808-0164

 

www.ResolutionProducts.com

 

Operation

 

 

Flood (ESN ending in 0) 

Alarm: when liquid rises 0.040 inches above sensor bottom. 
Tamper: when cover is opened. 
Supervisory: every hour. 

 

 

Freeze (ESN ending in 1) 

Alarm: when room temperature drops below 40F. 
Tamper: when cover is opened. 
Supervisory: every hour. 

 

 

Overheat (ESN ending in 2) 

Alarm: when room temperature rises above 100F. 
Tamper: when cover is opened. 
Supervisory: every hour. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Reviews: