RE212T 2GIG-Compatible Smoke & Heat Alarm
Features
•
UL217 Self-Contained Fire Alarm Device
•
Senses and alarms to Smoke per UL217
•
Heat alarm at 144 degrees.
•
Sleek design.
•
Cover tamper.
•
Strong, reliable RF signal.
•
3-5 year battery life on Panasonic CR123A battery.
•
Low Battery indication.
Key Instructions
1.
Attach the mounting plate
Locate on ceiling, as close to center as possible, away from corners.
Some local codes may allow wall mounting.
Mounting plate removes counter-clockwise
2.
Insert battery with MINUS towards the RED lever. Close battery door.
3.
Enroll sensor in panel:
Q1:
Select RF sensor # (01-48)
Zone number of your choice
Select RF sensor type
[09] 24-Hour Fire, or [16] 24-Hour Fire w/
Verification
(See Control Panel Installation
Manual)
Select RF sensor equip type
[1] Contact
Select RF sensor equip code
[0872] SMKE1-345 smoke detector
Select RF sensor serial number
Press Shift, Press Learn
Press and hold the TEST Button for 5 seconds
Select RF sensor Age
[1] New
Select RF sensor Loop number
[1] Motion
4.
Testing:
a) Place panel in Sensor Test mode
b) Press & hold TEST button until you hear the sounder beep.
c) Panel will go into alarm.
NOTE: Using Smoke-in-a-Can will cause an actual Fire Alarm.
Available for…
GE
Honeywell
2GIG
DSC
Answer
Question
RE212T_2GIG-Compat_Smoke_Instructions
Page
2
of
4
22-Feb-16
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
Operation
Situation
Sounder
LED
Wireless Signal
to Panel
Recovery
Actual smoke
Temporal 3
(Loud)
RED
(pulsing)
Wireless Fire
Alarm Signal sent
to panel
Silence an actual
alarm with the TEST
button. Sensor will
return to alarm if
smoke is still
present.
Press & hold
Test Button
Temporal 3
(Loud)
RED
(pulsing)
Sensor Alarm
signal to panel
Sensor: Release
button.
Panel: Restores after
alarm is cancled
Removing
Sensor from
Mount
Temporal 3
(Loud)
Yellow
(steady)
Tamper/Trouble
signal to be sent
to panel.
Restore by
remounting.
Low Battery
Yellow
(pulsing)
Hourly Check
Supervisories,
every hour
Maintenance
Needed
Temporal 3
(Loud)
Yellow
(Pulsing)
Supervisories Not
Sent
Replace Unit
Specifications
Approval:
UL217 Self-Contained Fire Alarm Device
Smoke Sensitivity:
1.31 – 2.28 %/ft (UL 217)
0.11 – 0.165 dB/m (EN54-7)
Smoke Sensing Technology:
Photoelectric
Heat Alarm Point:
135 – 149 F (UL 521)
Alarm Sound:
Temporal Three
Replacement Battery:
Panasonic CR123A
Temperature Range:
32 to 120 F (Long Term)
Humidity:
10 – 85% Relative Humidity
Housing dimensions:
4.7 inch diameter, 2.1 inch high
Design & Manufacture:
Resolution Products, Inc.
Specifications subject to change without notice.