RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
Installation Guide
RE601 CryptiX
™
-Compatible Standard Door / Window
Features
•
For sensing things that open or separate
•
Strong, reliable RF signal
•
10-15 year battery life
•
Cover tamper
•
Low Battery indication
•
3 total zones
•
Main reed magnet
•
2 Optional External Contacts
Enrollment
•
Place panel in enrollment mode.
•
Sensor enrollment signal can be sent by one of these two ways.
•
Remove the battery tab.
•
Pull cover off to tamper device.
•
To set up zone and configure the sensor, log into the web based dealer portal
Installation
•
Place sensor on a door or window using the mounting holes.
•
Below are recommendations for sensor locations.
Mounting holes
RE601_Cryptix-Compat_DWS_Instructions
24-Hour Tech Support Line: (715)808-0164
26-Feb-15
www.ResolutionProducts.com
•
Mount the sensor with magnet on the side of the sensor with the mark as
pictured below.
Optional External Contact Mounting and Wiring
•
Optional External contact wiring.
•
External Input #1: Outer Terminal Zone + Center Common Terminal
•
External Input #2: Inner Terminal Zone + Center Common Terminal
•
Optional external contact zones are: normally closed – alarm on open.
•
No end-of-line resistors on external contact zones.
Note:
External contacts not evaluated by ETL
Outer Terminal Zone
External Input #1
Center Common Terminal
Inner Terminal Zone
External Input #2
Magnet rests in
drilled hole on
top of door.
External contact is
wired to the door
window sensor
through a hole
drilled in the
doorframe
Magnet Mark