Installation Guide 
RE601 CryptiX

-Compatible Standard Door / Window

 

 

Features 

 

For sensing things that open or separate 

 

Strong, reliable RF signal 

 

10-15 year battery life 

 

Cover tamper 

 

Low Battery indication 

 

3 total zones 

 

Main reed  magnet 

 

2 Optional External Contacts  

   
Enrollment 

 

Place panel in enrollment mode.

 

 

Sensor enrollment signal can be sent by one of these two ways.

 

 

Remove the battery tab.

 

 

Pull cover off to tamper device.

 

 

To set up zone and configure the sensor, log into the web based dealer portal 

 

 

Installation 

 

Place sensor on a door or window using the mounting holes. 

 

 

 

 

Below are recommendations for sensor locations.

 

 

Mounting holes 

 

RE601_Cryptix-Compat_DWS_Instructions

 

 

24-Hour Tech Support Line: (715)808-0164

 

26-Feb-15

 

www.ResolutionProducts.com

 

 

 

Mount the sensor with magnet on the side of the sensor with the mark as 
pictured below. 

 

 

 

 

 
 
 
 
 
 
 
 
Optional External Contact Mounting and Wiring 
 

 

 
 

 

Optional External contact wiring. 

 

External Input #1: Outer Terminal Zone + Center Common Terminal 

 

External Input #2: Inner Terminal Zone + Center Common Terminal 

 

Optional external contact zones are: normally closed – alarm on open. 

 

No end-of-line resistors on external contact zones. 

 

 
 

 

 
 
 
 
 
 
 
 
 

 
 
 

Note:  

External contacts not evaluated by ETL

 

Outer Terminal Zone 

External Input #1 

Center Common Terminal

 

Inner Terminal Zone 

External Input #2 

Magnet rests in 
drilled hole on 
top of door.   

External contact is 
wired to the door 
window sensor 
through a hole 
drilled in the 
doorframe 

Magnet Mark  

 