resideo Honeywell Home RTH221 Series Owner'S Manual Download Page 1

Owner’s Manual

RTH2300B1012 

Read before installing

For help please visit  

resideo.com

RTH2300/RTH221  

 

Series

Programmable

Thermostat

Identify System Type

This thermostat is compatible with the following systems:

• 

Gas, oil or electric furnace

• 

Central air conditioner

• 

Hot water system with or without pump

• 

Millivolt system

• 

Central heating and cooling system

• 

Heat pump without auxiliary/backup heat

Do you need assistance? We are here to help.

Call 1-800-468-1502 for wiring assistance before returning 

the thermostat to the store.

This thermostat cannot be used on heat pumps with 
backup heat or on multistage systems.

Input: 2 x AAA batteries (1.5V each)

Summary of Contents for Honeywell Home RTH221 Series

Page 1: ...lectric furnace Central air conditioner Hot water system with or without pump Millivolt system Central heating and cooling system Heat pump without auxiliary backup heat Do you need assistance We are...

Page 2: ...e a thermostat containing mercury in the United States please refer to the Thermostat Recycling Corporation at www thermostat recycle org For mercury thermostat recycling in Canada please refer to Swi...

Page 3: ...ming and operation Setting the clock 11 Adjusting program schedules 12 Overriding schedules temporarily 13 Overriding schedules permanently 13 Compressor protection 14 Replace batteries 14 Appendices...

Page 4: ...gnation If you have an older thermostat with a sealed mercury tube turn to page 2 for proper disposal instructions Terminal designation C C MCR31537 2 Remove Old Thermostat Remove old thermostat but l...

Page 5: ...re labels If labels do not match letters on the thermostat check Alternate Wiring on page 6 and connect to terminal as shown see notes below Thermostat does not work on Heat Pumps with auxiliary backu...

Page 6: ...mp without auxiliary backup heat connect O or B not both If you do not have a heat pump do not connect B Wrap bare end of wire with electrical tape Place a jumper piece of wire between Y and W if you...

Page 7: ...eat systems This setting is for systems that allow the thermostat to control the fan in a call for heat if a fan wire is connected to the G terminal 9 Install Thermostat onto Wallplate Install thermos...

Page 8: ...you have other questions call us toll free at 1 800 468 1502 This thermostat works on 24 volt or 750 mV systems It will NOT work on multi stage conventional systems Advanced Installation Enter System...

Page 9: ...Celsius temperature display 0 Fahrenheit temperature display F 1 Celsius temperature display C 15 select Compressor Protection settings 1 On 0 Off 20 select clock display 0 12 hour display 1 24 hour...

Page 10: ...Switch is used to control your heating or cooling system Heat Heating system control Off All systems off Cool Cooling system control Display screen M32701 We Lo Batt Wake Set am Heat 75 On 6 30 Low b...

Page 11: ...the pre set settings shown in the table below since they can reduce your heating cooling expenses Wake Set to the time you awaken and the temperature you want during the morning until you leave for t...

Page 12: ...time periods Sa Su then press RUN to save exit NOTE Make sure the thermostat is set to the system you want to program Heat or Cool Mo Tu We Th Fr Sa Su Wake Set Schedule Set am 75 6 30 M32824 To adju...

Page 13: ...any time press RUN NOTE Make sure the thermostat is set to the system you want to control heat or cool Hold Set am 70 6 30 M32710 Set am 75 6 30 M32709 Program schedule override permanent Press HOLD...

Page 14: ...ttery replacement Install two fresh AAA batteries when Lo Batt flashes on the screen Lo Batt appears for 60 days before the batteries are depleted Replace batteries once a year or when you will be awa...

Page 15: ...ure is set lower than the Inside temperature Wait 5 minutes for the system to respond Temperature settings do not change Make sure heating and cooling temperatures are set to acceptable ranges Heat 40...

Page 16: ...e following address Resideo Return Goods 1985 Douglas Dr N Golden Valley MN 55422 or whether a replacement product can be sent to you This warranty does not cover removal or reinstallation costs This...

Page 17: ...ctrico Aire acondicionado central Sistema a agua caliente con o sin bomba Sistema de milivoltios Calefacci n y aire acondicionado centrales Bomba de calor sin calefacci n auxiliar Necesita ayuda Aqu...

Page 18: ...amente un termostato que contenga mercurio en los Estados Unidos consulte con Thermostat Recycling Corporation en www thermostat recycle org Para el reciclaje de termostatos con mercurio en Canad cons...

Page 19: ...l reloj 11 Ajuste de los cronogramas del programa 12 Anulaci n temporal de los cronogramas 13 Anulaci n permanente de los cronogramas 13 Protecci n del compresor 14 Reemplazo de la bater a 14 Ap ndice...

Page 20: ...terminales Si el termostato existente tiene un tubo de mercurio sellado vaya a la p gina 2 para obtener instrucciones sobre c mo desecharlo adecuadamente R tulos para los cables Designaci n de los ter...

Page 21: ...les Si las etiquetas no corresponden con las letras del termostato revise Conexi n alternativa en la p gina 6 y conecte al terminal como se indica refi rase a las notas que siguen El termostato no tra...

Page 22: ...rva conecte O o B no ambos Si no tiene una bomba de calor no conecte B Envuelva los extremos pelados del cable con cinta aislante Coloque un puente trozo de cable entre Y y W Aux si est utilizando una...

Page 23: ...Esta configuraci n es para sistemas que permitan que el termostato controle el ventilador en una orden de calefacci n si un cable del ventilador est conectado al terminal G 9 Instale el termostato en...

Page 24: ...de 120 240 voltios Gu a de instalaci n avanzada Ingrese la configuraci n del sistema Para ingresar la configuraci n del sistema presione y mantenga presionados los botones s arriba y t abajo hasta que...

Page 25: ...grados Fahrenheit F 1 Indicador de temperatura en grados Cent grados C 15 elegir la configuraci n de protecci n del compresor 1 Encendido 0 Apagado 20 elegir el visualizador del reloj 0 Visualizador...

Page 26: ...tablecer Presione para volver al cronograma del programa Pantalla de visualizaci n M32701 We Lo Batt Wake Set am Heat 75 On 6 30 Aviso de bater a baja vea la p gina 14 Estado del sistema Cool on fr o...

Page 27: ...s se muestran en el cuadro a continuaci n debido a que reducen los gastos de calefacci n y refrigeraci n WAKE Programe la hora en que se despierta y la temperatura que quiere durante la ma ana hasta q...

Page 28: ...do con el sistema que quiere programar Heat o Cool Mo Tu We Th Fr Wake Set Schedule Set am 75 6 30 M32706 Mo Tu We Th Fr Sa Su Wake Set Schedule Set am 75 6 30 M32824 Para ajustar los cronogramas del...

Page 29: ...tema que usted quiere controlar calor o fr o Temporary Wake Set am 70 6 30 M32708 Set am 75 6 30 M32709 Hold Set am 70 6 30 M32710 Set am 75 6 30 M32709 Programaci n de la anulaci n del cronograma per...

Page 30: ...la parte inferior para quitar el termostato de la placa para pared Gire el termostato e inserte bater as AAA alcalinas nuevas luego vuelva a instalar el termostato Ponga el conmutador del sistema en O...

Page 31: ...tura sea m s baja que la temperatura interna Espere 5 minutos para que responda el sistema Las configuraciones de la temperatura no cambian Aseg rese de que las temperaturas de calor y fr o est n conf...

Page 32: ...al cliente al 01 800 083 5925 para M xico ver tel fonos para otros pa ses donde se determinar si el producto debe regresarse o si se enviar un reemplazo del producto al consumidor sin costo alguno cu...

Reviews: