To transfer the water hardness °dH and °fH to ppm
(mg/l) the table in chapter Reference Data for
Hardness Adjustment.
5
Maintenance
In order to comply with EN 806-5, water fixtures must
be inspected and serviced on an annual basis.
As all maintenance work must be carried out by an
installation company, it is recommended that a
servicing contract should be taken out.
In accordance with EN 806-5, the following measures must
be taken:
5.1 Maintenance work
The operator must regularly perform the following checks to
guarantee that the unit functions properly.
Check the regenerative and refill after use.
Check the water hardness:
The hardness of drinking water and the set blended water
hardness must be checked 2x annually and the hardness of
the blended water must be corrected when required.
Check for leaks, visual inspection:
Check connection lines and connections for leaks. Check for
dirt in the regenerative storage area and brine cavity every
two months and clean and flush with clear water if necessary.
The intervals between checks are recommended minimums
and must be adjusted according to site conditions.
5.2 Operator responsibilities
All technical equipment requires regular servicing in order to
guarantee optimal functionality.
Keep yourself up to date with regard to the quality and
pressure ratio of the water which is to be treated. If the water
quality changes, the settings may need to be changed.
Consult a specialist if this is required.
Regular checks by the operator are required for the warranty
and proper functioning of the unit. The water softener must be
inspected regularly in accordance with the conditions of
operation and use.
5.3 Maintenance and wearing parts
Wearing parts must also be replaced within the prescribed
maintenance intervals in order to guarantee functionality and
fulfil the warranty conditions. The water softener should be
serviced once a year.
Wearing parts may only be replaced by qualified personnel
(fitters or after-sales service team).
We recommend that you enter into a maintenance agreement
with your fitter or the aftersales service team.
Use only cold, clear drinking water to clean the
surfaces! Any other cleansers cause damage to the
plastic components!
5.4 Disposal and environmental
information
At the end of product life please contact Customer Services
to arrange a new replacement for your softener.
Disposal of your softener and any electrical parts (e.g. 0.22
μ
F
capacitor battery,5.5 V) should only be carried out at
authorised WEEE recycling centres.
Hardness in
°dH
Min. average and max.
settings
Max. Average Min.
8.4
8 6 4
11.2 7 5 3
14.2 6 4 2
16.8 5 3 1
19.6 4 2 1
22.4 3 1 1
= Days between regeneration
Operator checks intervals:
After use:
Refill regeneration salt
2x Annually
Check pressure
2x Annually
Check water quality
1x Annually
Clean brine container