![Repak RE20 User Manual Download Page 87](http://html1.mh-extra.com/html/repak/re20/re20_user-manual_1443355087.webp)
87
4.4.11 Leak detection*
This menu is
accessed by pressing the ‘LEAK DETECTION’ button in the main menu
(see Figure 4.30)
The machine can be supplied with leak detection in the forming station. Leak detection works
together with the filler synchronisation. Upon the detection of a leaking package the filling
signal to the filler is prevented so no product is filled into it.
The sensitivity can be adjusted with the leak level, the lower this value the higher the
sensitivity.
Also the filling position has to be set. The input value has to be the number of strokes between
forming chamber and filler position, with the countstarting at the first stroke after the forming
station.
The value of the
set points
can be changed by pressing the numbers. A numeric keypad
(Figure 4.6) will appear, fill in the desired settings, press enter, now the numeric keypad will
disappear and the value for the SP has changed.
*Optional function!
Figure 4.30 Leak detection