Reonix Automation R2+ Quick Start Manual Download Page 1

R2+ Alarm Dialer

QUICKSTART 

GUIDE

Tools Required: 

Philips screwdriver (small) 

PPE (Recommended):

Safety gloves while removing 

and replacing the top plate

www.reonix.com

Form: RAI-SD-013

Issue Date: May 12, 2019 

Revision Date: Apr 26, 2020

Revision Number: 4

Configure Ethernet  Settings

Configure Email Settings

04

06

Confirm Connectivity

07

Configure Cellular Settings

05

The LAN settings are for the physical Ethernet port. 
If you are not using this function, it can be skipped. If 

a gateway is configured in the LAN Settings. The unit 

will use this path to connect with the Internet.

You must configure the email information service to 
send and receive email notifications. If you are not 

using this function, it can be skipped. Contact your 

email provider, if needed.

Navigate to the system page by clicking on the Tools 
page  on  drop-down  from  the  System  tab  located 
right  below  the  upper  SCADADroid®  banner.  Send 
yourself  an  email,  SMS,  and  voice  call  to  confirm 
connectivity.

The SCADADroid® has an input simulation feature. 
On the “STATUS” tab, ensure you turn off simulation 
by  toggling  the  Disable  Input  Simulation  button. 

Otherwise, the unit will not detect physical inputs 
changes.

The  cellular  settings  are  for  the  SIM  card  and  cell 

modem in the unit. If the cellular network is not being 

used or If your SIM card is text and voice only, skip this 
step. The only parameter that needs to be configured 

is the APN name. This setting will be dependent on 

your SIM card’s cellular provider. Contact the cellular 
provider for your SIM card’s APN. 

At a minimum, if you are using a cell modem, the cell 

modem type must appear, and the service provider 
field should appear if you have a SIM card. A reading 
of -113dbm means the SCADADroid® can detect no 
cellular coverage, despite a functioning SIM.

Disable Input Simulation

For further instructions, including instructions 

on how to set up shifts, add contacts, and 

add alarms, please refer to the user manual 

and the set-up manual. There are also 

detailed instructions on the use of Modbus, 

MQTT, and reporting functions in these 

manuals. The manual can be found at:

www.reonix.com/downloads

There are also support videos available at:

www.reonix.com/product-support-videos

Tel: (587) 351-5554

Toll Free: (855) 886-8506 

E-mail: [email protected]

Email address:

[email protected]

Incoming mail server type: 

IMAP or POP3

Incoming mail server (POP3/IMAP):

imap.gmail.com or pop.gmail.com

Incoming mail server port (IMAP/POP3): 

993  or 995

Keep mail on server: 

If delete is selected all retrieved mail will 

be deleted. Use only if email account 

is dedicated to SCADADroid®.

Outgoing mail server (SMTP):

smtp.gmail.com

Outgoing mail server port (SMTP): 

587

User: 

[email protected]

Password: 

Your password 

Last incoming check: 

It shows the last incoming mail time.

Last incoming status:

Show the status of the last email checked.

Reviews: