background image

21

Attachment 5: Warranty Certificate

Stove / hearth 

Type:  

………………………………………………………………………………………………………………………………

Serial number:  

………………………………………………………………………………………………………………………………

Date of purchase: 

……………………………………………………………………………………………………………………………

Dealer 

 

Name:  

………………………………………………………………………………………………………………………………

Street/No.:  

………………………………………………………………………………………………………………………………

 

ZIP code:  

………………………………………………………………………………………………………………………………

 

City:  

………………………………………………………………………………………………………………………………

Country:  

………………………………………………………………………………………………………………………………

 

Telephone:  

………………………………………………………………………………………………………………………………

 

Fax:  

………………………………………………………………………………………………………………………………

 

E-mail:  

………………………………………………………………………………………………………………………………

 

Signature: 

………………………………………………………………………………………………………………………………

  

 

User

Name:  

………………………………………………………………………………………………………………………………

Street/No.:  

………………………………………………………………………………………………………………………………

 

ZIP code:  

………………………………………………………………………………………………………………………………

 

City:  

………………………………………………………………………………………………………………………………

Country:  

………………………………………………………………………………………………………………………………

 

Telephone:  

………………………………………………………………………………………………………………………………

 

Fax:  

………………………………………………………………………………………………………………………………

 

E-mail:  

………………………………………………………………………………………………………………………………

 

Signature: 

………………………………………………………………………………………………………………………………

  

Summary of Contents for OPTIMA

Page 1: ...INSTALLATION AND USER MANUAL OPTIMA FIREPLACE INSERT RENY KACHELS Ganzestaartsedijk 14 5525 KC Duizel T 31497513125 F 31497518111 E info reny nl W www reny nl ...

Page 2: ...lopments and frenetic lifestyle there is an increasing need for a central location in houses used for people to relax This is why the ancient custom of using a wood stove is experiencing a true revival In addition heating using wood is a very sound choice environmentally Heating using wood is CO2 neutral When incinerated the wood releases the same substances that the tree extracted from the air A ...

Page 3: ...on 8 3 2 1 Heating air 8 3 2 2 Combustion air 8 3 3 First time stoking 8 3 4 Lighting 8 3 5 Stoking 9 3 6 Optimal stoking 9 3 7 Firewood consumption 10 3 8 Safety 10 4 MAINTENANCE 12 4 1 Seals 12 4 2 Out of use 12 4 3 Convection channels 12 4 4 Rotating parts 12 4 5 Warranty 12 4 6 Glass 12 4 7 Primary air channel 12 4 8 Coating 12 4 9 Smoke channel 12 4 10 Stoke bottom 12 4 11 Ventilators 13 4 12...

Page 4: ... the stove with the greatest possible care This guarantees the high quality you ve come to expect of RENY 1 2 SGI system RENY was the first manufacturer to introduce the Schoon Glas Injectie Clean Glass Injection system The stove has been designed in such a way that airflow is created just alongside the windowpane This creates optimal burning at that location which prevents windows from becoming c...

Page 5: ...rnt wood doesn t affect the environment in a more negative way than if it would have died in a natural way During the incineration of wood the amount of CO2 released is equal to the tree s air consumption A cycle in balance with nature that doesn t contribute to the greenhouse effect The RENY incineration system aims for optimal incineration using primary secondary and tertiary aeration The specia...

Page 6: ...hould be inspected again by your installer 2 3 Installation The hearth can be placed both in an existing and in a new built chimney piece Make sure that the foundation on which the hearth will be installed is strong enough to bear the weight of the hearth and the chimney In case of doubt always consult an expert Have your stove installed by a recognized installer only RENY offers no guarantee if t...

Page 7: ...iece If the hearth is equipped with convection ventilators provide an earthed power supply Cover the hearth on the upper back left and right side with approximately 10cm thick ceramic isolation wool Level the hearth The front of the chimney piece must be kept a few centimeters free from the hearth Connect the hearth directly gas leak proof to the chimney The diameter of the smoke channel may by no...

Page 8: ...crew M6x8 Figure 2 2 Mounting of the 3 sided frame 4 sided frame insert the two long side pieces into the left and right side of the hearth Then secure the frame on the upper and lower side with two M6x8 set screws on each side 2x set screw M6x8 OUTFLOW CONVECTION AIR INFLOW CONVECTION AIR INFLOW CONVECTION AIR INFLOW CONVECTION AIR INFLOW CONVECTION AIR INFLOW COMBUSTION AIR INFLOW EXTERNAL COMBU...

Page 9: ...radually During the first two stokings you need to limit opera tion to a tempered fire This helps you prevent the following problems Tearing of the vermiculite Damaging the coating Deforming the material The rope seals getting stuck During the first stokings it is possible that you will notice some pungent odor and smoke If this happens make sure that you properly ventilate the area During the nex...

Page 10: ...complete A larger air supply will improve incineration Avoid overloading white burning glow caused by lengthy burning with primary air fully open or by burning too much wood in one go The stove can then become overheated This may damage the stove At the end of the stoking cycle the primary aeration can be fully opened All remaining fuel will slowly sink to the middle of the stoke bottom Here addit...

Page 11: ... beech 4 0 kWh Efficiency Dynamic 82 0 Rated power 7 5 kW Efficiently utilized heating value 4 0 x 0 82 3 28 kWh Wood consumption per hour 7 5 3 28 2 29 kg Calculation example OPTIMA 70 Heating value 1 kg beech 4 0 kWh Efficiency Dynamic 81 0 Rated power 9 0 kW Efficiently utilized heating value 4 0 x 0 81 3 24 kWh Wood consumption per hour 9 0 3 24 2 78 kg Calculation example OPTIMA 80 Heating va...

Page 12: ... chimney fire Have the smoke channel swept clean at least once a year and more often if it is used intensely Prevent excessive soot within the channel therefore never burn freshly chopped wood but always clean and dry split wood Check hearth and chimney thoroughly for possible blockages when they haven t been used for an extended period Never cover the chimney piece with inflammable materials such...

Page 13: ...l components are used The device cannot be modified Also the warranty lapses in case of modification of whatever nature 4 6 Glass Do not wait too long with regard to cleaning the glass when there is soot on it This way you prevent the soot from burning in The glass can be cleaned using a moist cloth non scratching detergent or special window detergent available at your retailer To prevent cracking...

Page 14: ...ventilators and the convection space Assemble everything in the reversed order Always make sure that the ventilators are disconnected from the power supply 4 12 Vermiculite panels The vermiculite panels can be cleaned with a brush Check the cover for possible damage Cracks are no problem as long as they fit together nicely If pieces of a part of the cover are missing this part must be replaced imm...

Page 15: ...TERS SURFACE FINISH Ra TOLERANCES LINEAR ANGULAR FINISH DEBUR AND BREAK SHARP EDGES NAME SIGNATURE DATE MATERIAL WEIGHT DO NOT SCALE DRAWING REVISION RENY Openhaardenindustrie B V TITLE PART NUMBER SCALE SHEET 1 OF 1 A4 C Ganzestaartsedijk 14 5525 KC Duizel Tel 0497513125 Fax 0497518111 www reny nl Niels Castelijns 30 01 2012 00 Samenstelling Optima 53 1 9 87 Kg 14 ...

Page 16: ... FINISH Ra TOLERANCES LINEAR ANGULAR FINISH DEBUR AND BREAK SHARP EDGES NAME SIGNATURE DATE MATERIAL WEIGHT DO NOT SCALE DRAWING REVISION RENY Openhaardenindustrie B V TITLE PART NUMBER SCALE SHEET 1 OF 1 A4 C Ganzestaartsedijk 14 5525 KC Duizel Tel 0497513125 Fax 0497518111 www reny nl Niels Castelijns 30 01 2012 00 Samenstelling Optima 60 1 9 92 Kg ...

Page 17: ...ISH Ra TOLERANCES LINEAR ANGULAR FINISH DEBUR AND BREAK SHARP EDGES NAME SIGNATURE DATE MATERIAL WEIGHT DO NOT SCALE DRAWING REVISION RENY Openhaardenindustrie B V TITLE PART NUMBER SCALE SHEET 1 OF 1 A4 C Ganzestaartsedijk 14 5525 KC Duizel Tel 0497513125 Fax 0497518111 www reny nl Niels Castelijns 30 01 2012 00 Samenstelling Optima 70 1 10 123 Kg 16 ...

Page 18: ...CE FINISH Ra TOLERANCES LINEAR ANGULAR FINISH DEBUR AND BREAK SHARP EDGES NAME SIGNATURE DATE MATERIAL WEIGHT DO NOT SCALE DRAWING REVISION RENY Openhaardenindustrie B V TITLE PART NUMBER SCALE SHEET 1 OF 1 A4 C Ganzestaartsedijk 14 5525 KC Duizel Tel 0497513125 Fax 0497518111 www reny nl Niels Castelijns 30 01 2012 00 Samenstelling Optima 80 1 10 156 Kg 17 ...

Page 19: ... 600x523 Optima 53 4 sided frame 600x545 Optima 60 3 sided frame 660x523 Optima 60 4 sided frame 660x545 Optima 70 3 sided frame 760x573 Optima 70 4 sided frame 760x595 Optima 80 3 sided frame 860x623 Optima 80 4 sided frame 860x645 w h w h Frame 3 sided diagram Frame 4 sided diagram 18 ...

Page 20: ...ombustion chamber SGI spoiler Control secundary aeration Soot cover Smoke channel Ø150mm Ø200mm Heat shield steel Heat shield vermiculite Tertiary aeration Vermiculite cover Primary aeration Convection space Stoking bottom Connection external aeration Ø90mm 19 ...

Page 21: ...7 kg 92 kg 123 kg 156 kg Firewood beech wood Filling 1 31 kg 1 63 kg 1 95 kg 2 26 kg Primary air 0 0 0 0 Secundary air 75 75 80 80 Tertiary air 100 100 100 100 Burning time firewood 45 min 45 min 45 min 45 min Flue value Flue amount 7 0 g s 8 1 g s 9 2 g s 10 3 g s Flue temperature 234 C 243 C 253 C 262 C Vacuum 12 0 Pa 12 0 Pa 12 0 Pa 12 0 Pa Efficiency 83 30 82 0 81 0 79 20 CO at 13 O2 0 04 0 05...

Page 22: ...Warranty Certificate Stove hearth Type Serial number Date of purchase Dealer Name Street No ZIP code City Country Telephone Fax E mail Signature User Name Street No ZIP code City Country Telephone Fax E mail Signature ...

Page 23: ...t warranty period which is the result of a material and or manufacturing error the defective component is replaced with a new one through the dealer For those materials that are covered by warranty no wages and material costs are charged Any transportation costs will not be compensated Repairs will be executed at our factory The components listed below have a deviating warranty period Glass no war...

Page 24: ...acity and CO emission Manufacturer Model Nominal capacity Output classes High output Low output CO emission Low emission High emission Foundation capacity shield hearth and stove Ede The Netherlands Woodstove Reny Optima 6 3 10 0 kW 75 70 75 65 70 60 65 50 60 50 Attachment 6 ECO label 23 20130803 ...

Reviews: