63
en
Fixvent
®
Mono AK/UT
EVO
•
Fixscreen
®
Mono AK
EVO
When using a radio-controlled motor (RTS) or I/O Home motor, you must cut off the black cable
(the black wire does not have a working function with these types of motor).
Motor type
Mechanical (MSM)
Electronic (MSE)
Motor type
Radio-controlled (RTS)
IO home
Colour coding
Blue
N (Neutral)
Black
L1 (Phase 1)
Brown
L2 (Phase 2)
Yellow & green
PE (Physical Earthing)
PE
N
L2
L1
PE
N
L2
L1
Fixvent Mono AK/UT
EVO
and Fixscreen Mono AK
EVO
may not be switched in parallel (without a relay unit).
With the Fixvent Mono AK/
UT
EVO
and Fixscreen Mono
AK
EVO
, there may be dif-
ferent rolling up and down
speeds if using different
types of motors/engines
(e.g. electric and mechani-
cal) or when operating with
different types of
fabric roller barrels.
8.2.2.3 • Connecting the cable with UV-resistant sheathing (RR-F/RN-F)