BATTERY
BLUETOOTH LITHIUM IRON PHOSPHATE
12V 100Ah
Version 1.1
Page 1: ...BATTERY BLUETOOTH LITHIUM IRON PHOSPHATE 12V 100Ah Version 1 1 ...
Page 2: ...hquake war and terrorism Intentional or accidental misuse abuse neglect or improper maintenance and use under abnormal conditions Improper installation improper operation and malfunction of a peripheral device Contamination with hazardous substances or radiation Alterations to the product without express written consent from the manufacturer General Safety Information Please keep the battery away ...
Page 3: ...ted tools when working on the battery DO NOT wear jewelry or other metal objects when working on or around the battery Please ensure adequate and secure mounting of the battery Please use suitable handling equipment for safe transportation of the battery DO NOT dispose of the battery as household waste Please use recycling channels in ac cordance with local state and federal regulations ...
Page 4: ... Sizing Cables 07 Connecting Batteries in Bank 07 Securing Cable Connections 08 Installation Environment 09 Battery Operation 09 Activating Battery 09 Charging Battery 09 Discharging Battery 10 Battery Maintenance 10 Inspection 10 Cleaning 10 Checking Voltage 11 Battery Storage 11 Battery Management System 12 Warning and Protection 12 Battery Cell Balancing 13 Troubleshooting 14 Specifications 15 ...
Page 5: ...o the battery The built in Bluetooth module enables remote monitoring on mobile devices in real time Key Features Easy Upgrades Upgrades to lithium seamlessly with the standard BCI group size but a greater energy densi ty a deeper discharge capability a higher round trip efficiency and a faster charging speed Uncompromising Quality Ensures an exceptional lifespan with more than 2000 cycles 80 DOD ...
Page 6: ...05 Product Overview Identification of Parts Positive Terminal Negative Terminal Lifting Strap Dimensions 8 43in 214mm 8 72in 221 5mm 2 09in 53mm 6 77in 172mm 10 43in 265mm 12 99in 330mm ...
Page 7: ...of this section is only to serve as a guideline as all scenarios cannot be covered DO NOT short circuit the battery terminals Doing so can cause current bursts and lead to irreversible damage to the system and the battery Please verify the polarity before connecting the wiring Reversing polarity can and will de stroy the battery Please use circuit breakers fuses or disconnects appropriately sized ...
Page 8: ...able 310 15 B 16 for copper cables rated at 75 C 167 F operating at an ambient temperature of no more than 30 C 86 F Lengths in excess of 6 feet 1829 mm may require heavier gauge cable to avoid excess voltage drop in under sized wiring Connecting Batteries in Bank DO NOT connect batteries in series Doing so can cause catastrophic failure DO NOT connect batteries with different chemistries rated ca...
Page 9: ...re Please use an insulated wrench to tighten the cable connections To ensure good contacts between the cable lugs and the battery terminals please use the appropriate number of washers to allow for as much thread engagement as possible without bottoming out the terminal bolt The correct number of washers can be determined by hand tightening the terminal bolt with just the cable lug in place and ob...
Page 10: ...charge discharge current greater than 1A and measure the terminal voltage to validate Prior to long periods of storage please disconnect the battery from the system The battery will enter shelf mode automatically after 24 hours In shelf mode the battery has a low self discharge rate and can hold the charge for a longer period of time Parallel connected batteries can be activated simultaneously wit...
Page 11: ...ible Failure to do so may cause irreversible damage to the battery It is recommended to pair the battery with discharge equipment featuring low voltage dis connect During the standard discharging process the battery is discharged at a constant current of 30A until the battery voltage reaches 10V Safe discharging requires battery temperatures between 4 F and 140 F 20 C and 60 C Battery Maintenance ...
Page 12: ... due to self dis charge or parasitic loads Please stop using the battery until the fault can be corrected and the battery can be charged Battery Storage Please follow the tips below to ensure that the battery emerges from storage in a good condi tion Charge the battery to 30 50 and disconnect it from the system Store the battery in an open well ventilated dry clean area with temperatures between 1...
Page 13: ...y Voltage 12V Recover Battery Voltage 12 4V Charge Current 1A Protection Trigger Battery Voltage 10V Recover Battery Voltage 12 4V Charge Current 1A Battery Cell Undervoltage Warning Trigger Battery Cell Voltage 3 0V Recover Battery Cell Voltage 3 1V Charge Current 1A Protection Trigger Battery Cell Voltage 2 5V Recover Battery Voltage 3 1V Charge Current 1A Charge High Temperature Warning Trigger...
Page 14: ... Recover Discharge Current 100A Delay 1min Charge Current 1A Secondary Protection Trigger Discharge Current 120A Recover Discharge Current 100A Delay 1min Charge Current 1A Short Circuit Protection Trigger Discharge Current 1000A Recover Remove Short Circuit Delay 1min Charge Current 1A The warning status can only be monitored on the DC Home app The warning status will not affect the normal operat...
Page 15: ...battery with a current greater than 1A as soon as possible If the problem persists with a lithium iron phosphate compatible charging source and the correct voltage setting please first reduce the charge voltage by 0 2V 0 4V to balance the battery cells for 6 hours before attempting to fully charge the battery again If the battery temperature gets too high low during the operation and triggers the ...
Page 16: ...l Terminal Bolt Size M8 x 1 25 x 15 mm Recommended Terminal Torque 88 5 inch lbs 106 2 inch lbs 10 N m 12 N m Protection Rating IP65 Communication Protocol Modbus Certification MSDS UN38 3 FCC Operation Parameters Charge Voltage 14 4V Maximum Continuous Charge Current 50A Maximum Continuous Discharge Current 100A Charge Temperature Range 32 F 131 F 0 C 55 C Discharge Temperature Range 4 F 140 F 20...
Page 17: ......