background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 

PWM30LCD

 

RENOGY 30A Pulse Width Modulation Solar Charge 
Controller with LCD Manual 

 

2775 E. Philadelphia St., Ontario CA, 91761 

1-800-330-8678 

Summary of Contents for PWM30LCD

Page 1: ...PWM30LCD RENOGY 30A Pulse Width Modulation Solar Charge Controller with LCD Manual 2775 E Philadelphia St Ontario CA 91761 1 800 330 8678...

Page 2: ...6 Generated Amp hours 6 3 3 7 Consumed Amp hours 6 3 3 8 Ceasing Charging Voltage 7 3 3 9 Low Voltage Protection Function 7 3 3 10 Recovering Voltage 7 3 3 11 Load Work Mode 8 4 Protection Features a...

Page 3: ...ction Battery reversed protection Delayed auto restart after overloading protection The controller adopts the advanced Pulse Width Modulation PWM charging technology With range of 0 100 it can charge...

Page 4: ...nd below the controller 3 As shown in Fig 1 1 do the connections in the following order 1st Connect the DC loads 2nd Connect the battery or battery bank 3rd Connect the solar panel s 4 Plug the extern...

Page 5: ...tion of Buttons Circular toggle button This button is used to navigate all interface screens in a circular order as shown as Fig 3 1 Parameter adjusting button This button is used to increase the valu...

Page 6: ...5 seconds to save the new parameter 3 3 1 Battery Voltage The main screen shows the battery voltage and the battery level It also shows the charging and discharging state After using the navigation b...

Page 7: ...3 3 6 Generated Amp hours In this screen the controller will display the generated Amp hours from the solar panels since start up Pressing for more than 5 seconds will clear the generated A h Note Thi...

Page 8: ...ut if the voltage falls below a specific voltage This function helps prevent the battery from over discharging This parameter can be adjusted by pressing for more than 5 seconds Once the number on the...

Page 9: ...ad terminals start to supply power after sundown for the amount of hours indicated on the screen 1 to 23 hours 0h Indicates Dusk to Dawn Load is on all night long This parameter can be adjusted by pre...

Page 10: ...he picture on the right it means that the current load overloaded to 1 2 times of the rated current for 3 seconds The controller is now in overloading state with no output load Removing some of loads...

Page 11: ...ot reversed Bad blocking diodes from the solar panels can cause low voltage input check that the panel s open voltage and short circuit current is within specification 4 5 Starting Current Greater tha...

Page 12: ...Recovery adjustable 12 5V 25 0V No Load Loss 30mA Loop Voltage Drop 170mV Temperature Compensation 4mV Cell C Table 6 1 Electrical Characteristics 6 2 Mechanical Specifications Description Parameter...

Page 13: ...arranty period for the following products after August 1st 2015 INVT 500 12V INVT 1000 12V INVT 1500 12V INVT 2000 12V 3 year material and workmanship warranty AK 10FT 10 AK 10FT 12 AK 20FT 10 AK 20FT...

Page 14: ...a description of the defect loss of performance within the warranty period The Warrantor shall accept no returns of product s without the previous written request for this Within five 5 business days...

Page 15: ...ed to the Product The total cumulative liability to the Purchaser from all causes of action and all theories of liability will be limited to and will not exceed the purchase price of the Product paid...

Reviews: