889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
25
of 39
5.2.2
AUXILIARY VITAL OUTPUT MAPPING SCREENS
P
ARAMETER
...................Auxiliary Vital Output Mapping.
S
ETTINGS
........................4096 selections - any and all combinations of the four Loop
Status Inputs, four Vital Inputs, and the four Health Status
Inputs.
S
ETTING
D
ISPLAYED
......Bargraph indicates Loop Status Inputs, Vital Inputs, and/or
Health Status Inputs mapped to the Auxiliary Vital Outputs. In
Loop Status Input mode, the leftmost segment = Loop Status
Input 4, next segment = Loop Status Input 3, next segment =
Loop Status Input 2, next segment = Loop Status Input 1. In
Vital Input mode, the center four segments are used. The
leftmost center segment = Vital Input 4, next segment = Vital
Input 3, next segment = Vital Input 2, next segment = Vital
Input 1. In Health Status Input mode, the rightmost segment =
Health Status Input 1, next segment = Loop Status Input 2, next
segment = Loop Status Input 3, next segment = Loop Status
Input 4. The loop symbol indicates which Auxiliary Vital
Output the Loop Status Inputs, Vital Inputs, and/or Health
Status Inputs are being mapped to.
7-
SEGMENT
D
ISPLAY
......7-segment display will show currently selected setting. The
first character corresponds to the Loop Status Inputs mapped to
the Auxiliary Vital Outputs, the second character corresponds
to the Vital Inputs mapped to Auxiliary Vital Outputs, and the
third character corresponds to the Health Status Inputs mapped
to the Auxiliary Vital Outputs.
D
EFAULT
S
ETTINGS
........Auxiliary Vital Output 1 = 000. No Loop Status Inputs mapped
to Auxiliary Vital Output 1. No Vital Inputs mapped to
Auxiliary Vital Output 1. Health Status Input 1 not mapped to
Auxiliary Vital Output 1.
Auxiliary Vital Output 2= 000. No Loop Status Inputs mapped
to Auxiliary Vital Output 2. No Vital Inputs mapped to
Auxiliary Vital Output 2. Health Status Input 2 not mapped to
Auxiliary Vital Output 2.
Auxiliary Vital Output 3 = 000. No Loop Status Inputs mapped
to Auxiliary Vital Output 3, No Vital Inputs mapped to
Auxiliary Vital Output 3. Health Status Input 3 not mapped to
Auxiliary Vital Output 3.
Auxiliary Vital Output 4 = 000. No Loop Status Inputs mapped
to Auxiliary Vital Output 4. No Vital Inputs mapped to
Auxiliary Vital Output 4. Health Status Input 4 not mapped to
Auxiliary Vital Output 4.
E
XAMPLE
........................Loop Status Inputs 1, 2, & 3 mapped to Auxiliary Vital Output
1. No Vital Inputs mapped to Auxiliary Vital Output 1. Health
Status Inputs 1, 2, 3, & 4 mapped to Auxiliary Vital Output 1.
N
OTES
.............................The characters are displayed in Hexadecimal notation (Base
16).
When viewing and/or setting the Auxiliary Vital Output
mapping settings, use the FUNC pushbutton to advance to the
mapping settings of the next Auxiliary Vital Output.
An Auxiliary Vital Output is deactivated if no Loop Status
Inputs, Vital Inputs, or Health Status Inputs are mapped to it.
©
1