Model S-1212 Operating Instructions
P/N 889-1910-00
1
MODEL S-1212
Firmware Version 35.02
TWO CHANNEL LOOP DETECTOR
OPERATING INSTRUCTIONS
I
Factory Default Settings
Function
Channel 1 Channel 2
Loop Frequency (8 settings)
3
7
Sensitivity Level (OFF, 1 to 9, CALL)
6
6
Presence / Pulse Mode
Presence
Presence
Call Delay Time (0 to 255 seconds)
0
0
Call Extension Time (0 to 25.5 seconds)
0.0
0.0
Max Presence Time (OFF, 1 to 999 seconds)
OFF
OFF
End-of-Green (EOG)
OFF
OFF
Option 1 - Display Loop Inductance (L) *
OFF
OFF
Option 2 - Display % Loop Inductance Change (-
∆L/L) *
OFF
OFF
Option 3 - Call Extension Control
OFF
OFF
Option 4 - Noise Filter Disable *
OFF
OFF
Option 5 - Phase Green Loop Compensation
OFF
OFF
Option 6.0 - Display Vehicle Count
OFF
OFF
Option 6.1 - Reset Vehicle Count
OFF
OFF
Option 7 - Number of Loops for Vehicle Counting
04
04
Option 9 - Third Car Passage *
OFF
OFF
Option 10 - Directional Logic *
OFF
OFF
Option 11 - Audible Detect Signal **
OFF
OFF
Option 12 - Detector Disconnect **
Off
OFF
Detect ID
000
000
NOTES:
* These settings affect both channels.
** These settings affect each channel independently.
II
Viewing and Programming Detector Functions
i
Entering and Exiting Program Mode
•
Enter the Program mode by momentarily pressing the
FUNC
pushbutton. Use the
FUNC
pushbutton to step through the
functions described below.
•
Press the
CHAN
pushbutton to select the channel to view or make changes to. The channel that is in Program mode is
indicated by a flashing numbered-loop symbol at the bottom of the Liquid Crystal Display (LCD).
•
To change a function’s setting or to toggle a function
ON
or
OFF
, press the
(UP) or
(DOWN) pushbutton.
•
To exit the Program mode and return to the Normal display mode, press and hold the
CHAN
pushbutton continuously for one
second.
Loop Frequency
Loop Frequency can be adjusted from
1
to
8
. Press the
(UP) or
(DOWN) pushbutton to change the programmed Loop
Frequency. The filled segment on the bargraph indicates the setting. The left-most segment represents setting 1 and the right-most
segment represents setting 8. The LCD displays the actual operating frequency of the loop circuit. A separation of at least 5 KHz for
adjacent loops, not connected to the same detector, is recommended. The factory default setting is Loop Frequency 3 for Channel 1
and Loop Frequency 7 for Channel 2.
NOTE: Changing the Loop Frequency setting will reset the detector channel. The Loop
Frequency setting should not be changed while the detection zone is occupied
.
3510 E. Atlanta Ave.
Phoenix, AZ 85040 USA
Telephone: (480) 968-6407
Fax: (602) 437-1996
Website: www.editraffic.com