889-3819-00
MMU2-1600GE series Operations Manual Rev Apr 2020 Page
43
of 51
4.6.3.1
VIEW LOGS
MENU TEXT
MENU FUNCTION
VIEW DATE & TIME LOG
View the Date & Time log.
VIEW AC LINE LOG
View the AC Line log.
VIEW RESETS LOG
View the Resets log.
VIEW CONFIGURATIONS LOG
Access the View Configurations Log menu.
VIEW PRIOR FAULTS LOG
View the Prior Faults log.
VIEW SIGNAL SEQUENCE LOG
View the Signal Sequence log.
4.6.3.1.1
VIEW DATE & TIME LOG
The monitor records the thirty (30) most recent date and/or time changes in the Date & Time Log. Original Date
and Time, New Date and Time, and Up Time are recorded. This display is view only.
Use the left (◄) or right (►) pushbutton and the up (▲) or down (▼) pushbutton to scroll through the entries.
Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.3.1.2
VIEW AC LINE LOG
The monitor records the fifty (50) most recent changes in AC line status in the AC Line Log. Date and Time,
Event Type (Power Up, Power Down, Low Voltage, Low Voltage Recovery, Low Voltage Alarm, Low Voltage
Alarm Recovery, High Voltage Alarm, High Voltage Alarm Recovery, and Power Interrupt), AC Line Voltage /
Event Duration, and AC Line Frequency are recorded. This display is view only.
Use the left (◄) or right (►) pushbutton and the up (▲) or down (▼) pushbutton to scroll through the entries.
Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.3.1.3
VIEW RESETS LOG
The monitor records the twenty (20) most recent resets in the Resets Log. Date and Time, Fault Cleared and Reset
Source are recorded. This display is view only.
Press the
ENTER
pushbutton to view the Resets Log. Use the left (◄) or right (►) pushbutton and the up (▲) or
down (▼) pushbutton to scroll through the entries. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to
exit.
4.6.3.1.4
VIEW CONFIGURATION LOG MENU
MENU TEXT
MENU FUNCTION
VIEW CONFIG SETTINGS
View the currently active configuration settings.
COMPARE CURRENT TO PENDING
View the differences between the current configuration and any pending configuration
changes.
COMPARE CONFIG TO CURRENT
View the differences between any previous configuration and the current configuration.
COMPARE CONFIG TO PRIOR
View the differences between any previous configuration and the configuration
immediately preceding it.
4.6.3.1.4.1
VIEW CONFIGURATIONS SETTINGS
The monitor records the ten (10) most recent Monitor Configurations in the Configurations Log. Date and Time,
the total number of Active Features, and a list of the Active Features are recorded. This display is view only. The
Rollback Changes feature (Section 4.6.2.1.4) can be used to select and restore any one of the previously stored
configurations.
Use t
he left (◄) or right (►) pushbutton to select one of the ten (10) Configurations Settings to view. Use the up
(▲) or down (▼) pushbutton to scroll through the list of Active Features. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.3.1.4.2
COMPARE CURRENT TO PENDING
This feature allows the user to compare the pending configuration changes to the current monitor configuration.
The total number of different settings, a list of the different settings, and the current state and the pending state for
each feature are displayed. This display is view only. If the monitor is beeping due to a configuration change and
you are not sure what changes are pending, this screen will quickly identify the pending changes.
Use the up (▲) or down (▼) pushbutton to scroll through the li
st of features that are different. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.
4.6.3.1.4.3
COMPARE CONFIGURATION TO CURRENT
This feature allows the user to compare each of the previous nine (9) monitor configurations stored in the
Configurations Log to the current monitor configuration. Date and Time, the total number of Different Features, a
list of the Different Features, and the current state and the prior state for each feature are displayed. This display is
view only.
Use the left (◄) or right (►) pushbutton to select one of the nine (9) Configurations Settings to view/compare.
Use the up (▲) or down (▼) pushbutton to scroll through the list of features that are different. Press the
ENTER
pushbutton or the
ESCAPE
pushbutton to exit.