Wind speed transmitter manual (analog type)
Shandong Renke Control Technology Co., Ltd.
www.renkeer.com
8
speed change of 3m/s. The measured value is 5V-0V=5V. 5V*3/m/s/V=15m/s. The current wind
speed is 15m/s.
5. Common problems and solutions
Trouble phenomenon: no output or output error
possible reason:
1) The PLC calculation error is caused by the error corresponding to the range. Please refer to the technical
indicators in the first part of the range.
2) The wiring method is wrong or the wiring sequence is wrong.
3) The power supply voltage is wrong (24V power supply for 0-10V type).
4) The distance between the transmitter and the collector is too long, causing signal disturbance.
5) The PLC acquisition port is damaged.
6) The equipment is damaged.