Renishaw UCC MMI Installation Manual Download Page 1

UCC MMI installation guide

Documentation part number: H-1000-5362-01-A

UCC MMI installation guide

http://www.renishaw.com

 

 

Issued 11 2017

1

Summary of Contents for UCC MMI

Page 1: ...UCC MMI installation guide Documentation part number H 1000 5362 01 A UCC MMI installation guide http www renishaw com Issued 11 2017 1...

Page 2: ...e Microsoft Corporation All trademarks and trade names are acknowledged WEEE The use of this symbol on Renishaw products and or accompanying documentation indicates that the product should not be mixe...

Page 3: ...re or software without incurring any obligations to make changes to Renishaw equipment previously sold Packaging To aid end user recycling and disposal the materials used in the different components o...

Page 4: ...EU declaration of conformity Contact Renishaw plc or visit www renishaw com productcompliance for the full EU declaration UCC MMI installation guide http www renishaw com Issued 11 2017 4...

Page 5: ...s equipment in a residential area is likely to cause harmful interference in which case you will be required to correct the interference at your own expense Information to user 47CFR section 15 21 The...

Page 6: ...s Installation category II The UCC MMI is isolated from ac power by disconnection of the IEC mains connector from the supplied PSU If any additional means of isolation is required it must be specified...

Page 7: ...orage 80 maximum non condensing for temperatures up to 31 C Linear decrease to 50 at 50 C Transient voltages Installation category II Pollution degree 2 NOTE It may be necessary to house UCC MMI in a...

Page 8: ...e earth This is to avoid earth loops However the protective grounding must be continuous between the controller and all other equipment in the installation All cable connectors should be secured to th...

Page 9: ...s A rack mounting kit is available as an optional extra The UCC MMI has the capability to Control three axes of a CMM Accept input signals from air pressure contactor feedback and all axis inner and o...

Page 10: ...Connections for the TP20 TP1 TP2 and TP6 touch trigger probes I O connections to limit switches air pressure and other digital inputs and outputs TTP interface The UCC MMI unit incorporates the circu...

Page 11: ...off waiting about 10 seconds then turning it on again If the problem persists the unit needs attention If the initialisation tests are successful then the power on LED will remain lit and the error L...

Page 12: ...Probe seated LED When the probe is not deflected the probe seated LED is on When the probe is deflected the probe seated LED is off UCC MMI installation guide http www renishaw com Issued 11 2017 12...

Page 13: ...ntial bonding point 2 X axis scale 15 way high density D 3 Y axis scale 15 way high density D 4 Z axis scale 15 way high density D 5 PC connection USB 6 Not used 7 PICS 9 way D 8 Blank 9 Not used 10 N...

Page 14: ...default condition is a normally closed circuit opening on the event Input blanking Switching polarity can be adjusted in the software or by using hardware In UCCassist 2 all inputs can have polarity...

Page 15: ...Generic UCC I O connector UCC MMI installation guide http www renishaw com Issued 11 2017 15...

Page 16: ...dhead cables are used the recommended cable sizes are 3 m of head cable and 15 m of extension cable or an equivalent combination The head cable has 5 times the resistance of the extension cable CAUTIO...

Page 17: ...Reference mark 13 B signal 14 A signal 15 Inner screen Shell Screen The UCC MMI is capable of supporting both single and dual limit switch RG22 readheads The electronic circuits can interface either t...

Page 18: ...tch inputs UCC MMI input circuit for CMM readhead error input UCC MMI to CMM measuring scale readhead The maximum specified cable length is 18 m assuming that individual cable wire cross sectional are...

Page 19: ...Write to controller port The output is pulled up to the 24 V rail by a 20 k resistor when inactive and will be pulled down to the 24 V return line via an NPN transistor when activated There is an exc...

Page 20: ...cation for USB connections When the UCC MMI is connected to the PC and power applied to the unit Windows will automatically detect the new hardware and start the Windows hardware installation wizard T...

Page 21: ...connector is a 9 pin D socket pinout as follows Pin number Function 1 PICS STOP 2 PICS probe power off PPOFF 3 0 V 4 PICS LED anode 5 Probe signal 6 Reserved 7 PICS probe damping PDAMP 8 PICS LED off...

Page 22: ...oses in place of the controller 24 V supply but its negative rail must be connected to the controller 24 V return line Controller output supplies The UCC MMI produces a 24 V current limited supply wit...

Page 23: ...ion A minimum specification of 1 GHz processor speed and 256 MB RAM is recommended For UCC MMI only one free USB port is required for the communication It is recommended NOT to use a USB hub because o...

Page 24: ...CMM is running within the specified operational tolerances Error mapping for manual machines ISO 10360 2 CMM certification UCC MMI system components The part numbers of the UCC MMI kits and upgrades a...

Page 25: ...rotective bonding circuit Insulation resistance tests Voltage tests Protection against residual voltages Functional tests particularly those related to safety and safeguarding Following replacement mo...

Page 26: ...arth continuity ground bonding test may be applied between the protective earth pin of the mains connector and the metal case at a test current of no greater than 25 A Periodical safety checks should...

Page 27: ...ails please visit our main website at www renishaw com contact Renishaw plc New Mills Wotton under Edge Gloucestershire GL12 8JR United Kingdom T 44 0 1453 524524 F 44 0 1453 524901 www renishaw com c...