Renishaw TONiC diagnostic kit User Manual Download Page 3

TONiC diagnostic kit

User guide 

1

TONiC

User guide 

1. General information

1.1. Minimum system requirements

  Microsoft Windows 8, Windows 7 or Windows XP 

  Microsoft .NET Framework 4.0 Full

  USB port 

  Internet connection for software download

1.2. General specifications

Power supply

5 V ±10%

The dongle can be powered from the USB port or an external 
5 V dc supply with the requirements for SELV or standard IEC 
60950-1
Dongle current consumption < 50 mA
Dongle interface current consumption < 100 mA

Ripple

< 200mVpp maximum at frequency up to 500 KHz

Temperature

Storage

-20 °C to +70 °C

Operating

0°C  to +70 °C

Humidity

95% relative humidity (non-condensing) to IEC 60068-2-78

Sealing

IP20

1.3. Legal notices

Copyright

© 2015-2021 Renishaw plc. All rights reserved.
This document may not be copied or reproduced in whole or in part, or transferred to any other media or language by any 
means, without the prior written permission of Renishaw.

Trade marks

RENISHAW

®

 and the probe symbol are registered trade marks of Renishaw plc. Renishaw product names, designations and the 

mark ‘apply innovation’ are trade marks of Renishaw plc or its subsidiaries.
Other brand, product or company names are trade marks of their respective owners.

Disclaimer

WHILE CONSIDERABLE EFFORT WAS MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION, ALL 
WARRANTIES, CONDITIONS, REPRESENTATIONS AND LIABILITY, HOWSOEVER ARISING, ARE EXCLUDED TO THE 
EXTENT PERMITTED BY LAW.
RENISHAW RESERVES THE RIGHT TO MAKE CHANGES TO THIS DOCUMENT AND TO THE EQUIPMENT, AND / OR SOFTWARE 
AND THE SPECIFICATION DESCRIBED HEREIN WITHOUT OBLIGATION TO PROVIDE NOTICE OF SUCH CHANGES.

Terms and conditions and warranty

Unless you and Renishaw have agreed and signed a separate written agreement, the equipment and/or software are sold 
subject to the Renishaw Standard Terms and Conditions supplied with such equipment and/or software, or available on request 
from your local Renishaw office.
Renishaw warrants its equipment and software for a limited period (as set out in the Standard Terms and Conditions), provided 
that they are installed and used exactly as defined in associated Renishaw documentation. You should consult these Standard 
Terms and Conditions to find out the full details of your warranty.
Equipment and/or software purchased by you from a third-party supplier is subject to separate terms and conditions supplied 
with such equipment and/or software. You should contact your third-party supplier for details.

Product compliance

Renishaw plc declares that TONiC diagnostic kit complies with the applicable standards and regulations.
A copy of the EU declaration of conformity is available from our website at 

www.renishaw.com/productcompliance

.

Summary of Contents for TONiC diagnostic kit

Page 1: ...User guide M 9589 9081 02 A TONiC diagnostic kit...

Page 2: ...tal Ti interface Ti0004 Ti4000 6 3 1 2 TONiC with digital Ti interface Ti10KD or Ti20KD or analogue Ti interface Ti0000 6 3 2 Starting the software 7 3 3 Using the software 8 3 3 1 Signal size 8 3 3 2...

Page 3: ...MADE TO VERIFY THE ACCURACY OF THIS DOCUMENT AT PUBLICATION ALL WARRANTIES CONDITIONS REPRESENTATIONS AND LIABILITY HOWSOEVER ARISING ARE EXCLUDED TO THE EXTENT PERMITTED BY LAW RENISHAW RESERVES THE...

Page 4: ...be used with the unit to ensure compliance Further information Further information relating to the TONiC encoder range can be found in the TONiC system Data sheet and Installation guides These can be...

Page 5: ...ld be used and replaced when worn or damaged Packs of 10 replacement PCB s are available to order Item 6 A 9411 0016 Item 7 A 9411 0017 Item Description Quantity 1 Dongle 1 2 Dongle interface 1 3 USB...

Page 6: ...rface dimensions 1 5 Dongle dimensions Dimensions and tolerances in mm 62 33 3 12 5 33 3 39 Communication LED USB port 1 7 Signals Dongle interface Dongle Function Signal Output pin male 15 way D type...

Page 7: ...the screen and the installation program will automatically run through the installation process NOTE On Windows 8 it will ask Do you want to allow the following program from an unknown publisher to m...

Page 8: ...6 sacrificial interconnect PCB for TONiC or ATOM cabled readheads Item 5 Interface cable for TONiC or ATOM readheads Item 2 dongle interface Item 1 dongle Item 3 USB cable Do not connect the readhead...

Page 9: ...USB port to the PC See 3 1 Connecting the system page 6 for details on connecting the TONiC readhead to the dongle The Start page will then become active The PSU voltage will display USB showing it i...

Page 10: ...nal is activated The tone gets higher as the signal level increases NOTE When the TONiC dongle is connected the diagnostic LED on the dongle interface or Ti interface will flash orange it will not dis...

Page 11: ...t of bar not within the boxes TONiC User guide 3 3 3 Pitch indicator The pitch of the readhead is displayed as a spirit level To ensure the correct pitch the bubble should be positioned between the tw...

Page 12: ...he readhead starts double flashing Move the readhead backwards and forwards across the chosen reference mark The CAL button will turn grey and the signal size and reference mark displays will be react...

Page 13: ...used between the readhead and the dongle interface 3 1 Connecting the system page 6 The dongle must be used with the dongle interface unless using a Ti0004 Ti4000 Check connections between the dongle...

Page 14: ...pressing and holding the CAL button on the dongle interface whilst cycling the power See the relevant TONiC installation guide for details of the calibration routine and restoring factory defaults 4...

Page 15: ...eady to use 5 2 Manual hardware driver installation If the drivers have not automatically installed they can be manually installed Browse C Program files x86 Renishaw TONiC diagnostic Depending upon i...

Page 16: ...0 1453 524901 E uk renishaw com www renishaw com For worldwide contact details visit www renishaw com contact Part no M 9589 9081 02 A Issued 02 2021 M 9589 9081 02 Renishaw plc Registered in England...